 When SNMP is enabled, the projector is able to send Failure/Warning Alerts to a 
specifi ed PC. 
 • It is recommended that SNMP functions be carried out by a network 
administrator.  
 • SNMP management software must be installed on the computer to monitor 
the projector via SNMP.   
 NOTE 
 SNMP settings   (   
 
25
 Confi gure the following items via a web browser to use SNMP. 
  Example: If the IP address of the projector is set to 192.168.1.10/:  
 • A Network Restart is required after the SNMP Trap confi guration 
settings have been changed. Click  [Network Restart]  and confi gure the 
following items. 
 NOTE 
  5) Click  [Security Settings]  on the main menu. 
  6) Click  [SNMP]  and set the Community Name on the screen that is displayed. 
 • A Network Restart is required after the Community Name has been 
changed. 
 • Click  [Network Restart]  and confi gure the following items.   
 NOTE 
  7)  Confi gure the settings for Trap transmission of Failures/Warnings. Click 
 [Alert Settings]  on the main menu and select the Failure/Warning item to be 
confi gured. 
  8)  Click the  [Enable]  check box to send out the SNMP trap for Failures/Warnings. 
Clear the  [Enable]  check box when SNMP trap transmission is not required. 
  9) Click the  [Apply]  button to save the settings. 
  1) Enter  [http://192.168.1.10]  into the address bar of the web browser. 
  2) Enter the Administrator ID and Password and click  [Logon ]. 
  3) Click  [Port Settings]  on the main menu. 
  4)  Click the  [Enable]  check box to open the SNMP Port.
Set the IP address to send the SNMP Trap to when a  Failure/Warning occurs. 
4. Utilize projector – Advanced -
4.5 Projector management via SNMP