    ATA/ATAPI specifications 
Transfer mode 
MODE 0 
MODE 1 
MODE 2 
MODE 3 
MODE 4 
MODE 5 
Symbo
Meaning 
Min. Max. Min.
Max.
Min.
Max.
Min.
Max.
Min.
Max. Min. Max.
t
CYC
 
Cycle time 
112  73  54  39  25  16.8  
t
2CYC
 
Two cycle time 
230  153
 115
 86  57  38  
t
DS
 
Data setup time 
15.0  10.0
 7.0
 7.0
 5.0
 4.0  
t
DH
 
Data hold time 
5.0  5.0
 5.0
 5.0
 5.0
 4.6  
t
DVS
 
Data valid setup time 
70.0  48.0
 31.0
 20.0
  6.7
  4.8   
t
DVH
 
Data valid hold time   
6.2  6.2
 6.2
 6.2
 6.2
 4.8  
t
CS
 
CRC setup time 
15.0  10.0
 7.0
 7.0
 5.0
 5.0  
t
CH
 
CRC hold time 
5.0  5.0
 5.0
 5.0
 5.0
 5.0  
t
CVS
 
CRC valid setup time 
70.0  48.0
 31.0
 20.0
  6.7
 10.0  
t
CVH
 
CRC valid hold time 
6.2  6.2
 6.2
 6.2
 6.2
 10.0  
t
ZFS
 
Strobe released to driving 
0  0  0  0  0  35  
t
DZFS
 
Data released to driving 
70.0  48.0
 31.0
 20.0
  6.7
  25   
t
FS
 
First STROBE time 
0 230 0 200
0 170
0 130
0 120 0  90 
t
LI
 
Limit interlock time 
0 150 0 150
0 150
0 100
0 100 0  75 
t
MLI
 
Interlock time min. 
20  20  20  20  20  20  
t
UI
 
Unlimited interlock   
0  0  0  0  0  0  
t
AZ
 
Allowed to release 
 10  10  10  10  10  10 
t
ZAH
 
Delay time 
20  20  20  20  20  20  
t
ZAD
 
Delay time 
0  0  0  0  0  0  
t
ENV
 
Envelope time 
20 70 20 70 20 70 20 55 20 55 20 50 
t
RFS
 
Ready to final Strobe 
 75  70  60  60  60  50 
t
RP
 
Ready to pause 
160  125
 100
 100
 100
  85   
t
IORDYZ
 
Pullup before IORDY 
 20  20  20  20  20  20 
t
ZIORDY
 
Wait before IORDY 
0  0  0  0  0  0  
t
ACK
 
Setup hold for DACK 
20  20  20  20  20  20  
t
SS
 
Strobe to DREQ/Stop 
50  50  50  50  50  50