WORD 47: 
bit 15 - 8    shall be set to 80h 
bit 7 - 0      Maximum number of sectors that can be transferred per interrupt on READ/WRITE MULTIPLE 
commands. 
 
The default value for this WORD is 8010h. 
WORD 48: Reserved 
WORD 49: Capabilities 
bit 15-14 
0=Reserved 
bit 13 
1=Standby timer value shall be as specified in ATA-/ ATAPI-6 specification   
 
 
0=Standby timer value are vendor specific 
bit 12 
Reserved (For advanced PIO mode support) 
bit 11 
1=IORDY is supported. 
bit 10 
1=IORDY function can be disabled. 
bit  9 
1=LBA supported 
bit  8 
1=DMA supported 
bit  7- 0   Reserved 
 
The value for this WORD is 2F00h. 
 
WORD 50: Capabilities 
bit 15      0  (Fixed) 
bit 14      1  (Fixed) 
bit 13-1    Reserved 
bit  0     1=device has a minimum Standby timer value that is device specific. 
 
Standby timer value is set to 5 minutes or more. The value for this WORD is 4000h. 
 
WORD 51: PIO data transfer cycle timing mode 
bit 15- 8 
PIO data transfer cycle timing mode 
bit 7- 0 
Reserved 
 
The value returned in Bits 15-8 should fall into one of the mode 0 through mode.   
Note:    For backwards compatibility with BIOS written before Word 64 was defined for advanced modes, a 
device reports in Word 51 the highest original PIO mode (i.e.    PIO mode 0, 1, or 2) it can support. 
The value for this WORD is 0200h. 
WORD 52: Reserved 
WORD 53:   
    bit15- 3   Reserved 
    bit 2   
1= the fields reported in word      88  is valid 
        bit 1     
1= the fields reported in words 64∼70 are valid   
        bit 0     
1= the fields reported in words 54∼58 are valid 
 
If the number of heads and sectors exceed the drive parameter, bit 0 and related WORD 54-58 shall be 
cleared to 0. The default value for this WORD is 0007h. 
 
WORD 54: Number of current cylinders defined by INITIALIZE DEVICE PARAMETERS command 
WORD 55: Number of current heads defined by INITIALIZE DEVICE PARAMETERS command 
WORD 56: Number of current sectors/track defined by INITIALIZE DEVICE PARAMETERS command