Alliance Laundry Systems Stacked Drying Tumbler 用户手册

下载
页码 38
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation Instructions
19
M412060
If the gas service is not the same as that specified, DO 
NOT CONNECT THE GAS LINE TO THE 
TUMBLER! It will first be necessary to convert the 
gas burner orifices.
IMPORTANT: Any product revisions or 
conversions must be made by the Manufacturer’s 
Authorized Dealers, Distributors or local service 
personnel.
Purge air and sediment from the gas service line before 
connecting it loosely to the tumbler. Purge remaining 
air until odor of gas is detected, then tighten 
connection. Use pipe compound, resistant to actions of 
L.P. gas, on all pipe threads.
To reduce the risk of fire or explosion:
• The tumbler and its individual shut-off 
valve must be disconnected from the gas 
supply piping system during any 
pressure testing of that system at test 
pressures in excess of 1/2 psig (3.45 
kPa).
• The tumbler must be isolated from the 
gas supply piping system by closing its 
individual manual shut-off valve during 
any pressure testing of the gas supply 
piping system at test pressure equal to or 
less than 1/2 psig (3.45 kPa).
W648
WARNING
Check all pipe connections, internal and 
external, for gas leaks using a soapy 
solution. To reduce the risk of explosion or 
fire, DO NOT USE AN OPEN FLAME TO 
CHECK FOR LEAKS! Gas connections 
should be checked annually for leakage.
W649
WARNING