DISCONNECT ELECTRIC 
POWER SUPPLY 
AND LOCK OUT 
SERVICE PANEL BEFORE 
SERVICING UNIT
W A R N I N G
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS,  
OBSERVE THE FOLLOWING:
 
1. For general ventilating use only. Do not use to exhaust hazard-
ous or explosive materials and vapors.
 
2. To avoid motor bearing damage and noisy/unbalanced impellers, 
keep drywall spray, construction dust, etc. off power unit.
 
3. DO NOT install this product in a wall. This product is designed 
for installation in ceilings up to a 12/12 pitch (45 degrees). 
Ductwork must point upward.
 
4. Please read specification label on product for further information 
and requirements.
PREVENTATIVE MAINTENANCE
A clean fan provides better service. Disconnect the power supply and 
clean the fan as listed below.
TO CLEAN GRILLE: Use a mild detergent, such as dishwashing 
liquid, and a soft cloth. DO NOT use abrasive cloths, steel wool pads 
or scouring powders.
TO CLEAN FAN ASSEMBLY: Unplug motor cord from receptacle. 
To remove motor plate, find the single tab on the motor plate (located 
next to the receptacle). Push up rear motor plate tab while pushing 
out on the side of the housing or insert a screwdriver into the slot in 
the housing (next to tab) and twist screwdriver. Gently vacuum fan, 
motor and interior of housing.
METAL AND ELECTRICAL PARTS SHOULD NEVER BE IMMERSED 
IN WATER.
MAINTENANCE
The motor is permanently lubricated and never needs oiling. If the 
motor bearings are making excessive or unusual noises, replace the 
motor with the exact service motor. You should replace the impeller at 
the same time.
C A U T I O N
W A R N I N G
  1. Use this unit only in a manner intended by the manufacturer. 
If you have questions, contact the manufacturer.
 
2. Before servicing or cleaning the unit, switch power off at ser-
vice panel and lock the service disconnecting means to prevent 
power from being switched on accidentally. When the service 
disconnecting means cannot be locked, securely fasten a 
prominent warning device, such as a tag, to the service panel. 
 
3. Installation work and electrical wiring must be done by quali-
fied person(s) in accordance with all applicable codes and 
standards, including fire-rated construction.
 
4. Sufficient air is needed for proper combustion and exhausting 
of gasses through the flue (chimney) of fuel burning equipment 
to prevent backdrafting. Follow the heating equipment manufac-
turer’s guideline and safety standards,such as those published 
by the National Fire Prevention Association (NFPA), and the 
American Society for Heating, Refrigeration and Air-Conditioning 
Engineers (ASHRAE), and the local code authorities.
 
5. When cutting or drilling into wall(s) or ceiling, do not damage 
electrical wiring or other hidden utilities.
 
6. Ducted fans must always be vented to the outdoors. 
 
7. If this unit is to be installed over a tub or shower, it must be 
marked as appropriate for the application and be connected to a 
GFCI (Ground Fault Circuit Interrupter) – protected branch circuit.
 
8. Never place a switch where it can be reached from a tub or 
shower.
 
9. Install fan at least 5 feet (1.52 m) above the floor.
 
10. This unit must be grounded.
 
11. Unit must not be installed in a ceiling thermally insulated to a 
value greater than R40.
 12. For supply connection, use wires suitable for at least 
90º C (194º F).
Do Not Install Above
Or Inside This Area
Cooking
Equipment
Floor
45°
45°
COOKING AREA