Bosch ndn-921 用户手册

下载
页码 134
FlexiDomeHD 720p IP Camera
Advanced Mode | en
51
Bosch Security Systems
Installation and Operation Manual
AR18-10-B013 | v1.52 | 2011.06
5.
Click one of the entries in the table to make changes. The 
entry is highlighted.
6.
Click Delete to remove the entry from the table.
7.
Choose other values from the list boxes under the table, to 
change the selected entry. Changes are immediate.
8.
If there are empty lines at the bottom of the table, for 
example after deletions, add new data by marking the row 
and selecting values from the list boxes.
9.
When finished, click OK to save and activate the table.
Note:
If a table is not created, there is no automatic switching. When 
editing the table, note that values occur in linked pairs (DST 
start and end dates).
Time server IP address
The camera can receive the time signal from a time server using 
various time server protocols and then use it to set the internal 
clock. The device polls the time signal automatically once every 
minute. Enter the IP address of a time server.
Time server type
Select the protocol that is supported by the selected time 
server. It is recommended to select the SNTP server protocol. 
This protocol provides high accuracy and is required for special 
applications and future function extensions. Select Time server 
if the server uses the RFC 868 protocol.
9.2.4
Display Stamping
Various overlays or stamps in the video image provide 
important supplementary information. These overlays can be 
enabled individually and arranged on the image in a clear 
manner.
Camera name stamping
This field sets the position of the camera name overlay. It can 
be displayed at the Top, at the Bottom, or at a position of 
choice using the Custom option, or it can be set to Off for no 
overlay information.