MC-Series System Installation & Testing 
System Description 
RadioFrame Networks, Inc.
  
27 
2.4.3 
Channel Service Unit (CSU) 
The Channel Service Unit (CSU) provides the T1 connection between the iSC-3 and the 
telephone company that provides the T1 line. The CSU provides surge protection to the T1 line 
and loop-back testing for the telephone company. 
For more information about the CSU, refer to the manufacturer's documentation. 
2.4.4 
GPS Antenna System 
The Global Positioning System (GPS) antenna provides GPS signals to the iSC-3, which 
constructs the timing reference for the MC-Series System hardware. One GPS antenna with a 
dedicated 50ohm coax is required for each iSC-3.  
2.4.5 Powerplant 
The MC-Series System cabinet is powered by a nominal –48VDC powerplant supplied by the 
customer. The powerplant may be installed in the cabinet or used externally. The cabinet is 
shipped with a Power Distribution Unit (PDU) installed in the cabinet. The PDU contains circuit 
breakers that provide overcurrent protection for MC-Series loads. 
2.5 Specifications 
2.5.1 Dimensions 
 
Equipment Dimensions 
Supplier 
Component 
Width 
Depth 
Height 
RadioFrame Networks 
cabinet 
23.5” 
25.5” 
79” 
42U 
 BIC 
19” 
13” 
7” 
4U 
 AIC 
19” 
13” 
7” 
4U 
 RBS 
19” 
13” 
7” 
4U 
 RF 
Shelf 
19” 
13” 
7” 
4U 
 PDU 
19” 
10” 
1.75” 
1U 
Non-RFN iSC-3 
 
19” 
9” 
1.75” 
1U 
 EAS 
19” 
15” 
1.75” 
1U 
 CSU 
19” 
12.5” 
1.75” 
1U