7.10 RF 
Troubleshooting 
The terminal monitors the status of the outdoor modem unit and reports any fault 
conditions in the system event log. The following table lists the general fault conditions 
reported by the terminal. 
Table 39: Troubleshooting - RF Error Diagnostics 
Error Type 
Description 
IF PLL Unlocked 
The PLL (Phase Locked Loop) section within the terminal 
experienced an error. The System Fault LED may light. Try 
resetting the unit. 
Communication Error 
Over IF Cable 
Communication between the terminal and the modem failed. 
Check the IF cable and connectors. 
Outdoor Unit 
Temperature is too 
High. Air Interface 
Disabled for 15 Minutes 
The internal temperature of the modem is above 82C 
(180°F). The modem shuts down to allow cooling. 
Outdoor Unit Power 
Supply Error 
Displays a fault in the modem power supply. This error could 
be due to a problem with the internal power supply or with 
the power source from the terminal. If the 'Low DC Voltage 
At Radio' error is also indicated, (see below) check the IF 
cable and connectors. If the 'Low DC Voltage At Radio' error 
is not indicated, the modem requires servicing. 
Outdoor Unit 24V Error 
The DC voltage at the modem (carried by the IF cable from 
the terminal) is lower than the required 24 VDC. Check the 
IF cable and connectors. The minimum required voltage for 
operation is 12 VDC. 
Air Interface Disabled 
The radio is disabled. 
Cable Compensation 
Failed 
The measured IF cable compensation is out of specification. 
Invalid Radio 
The attached radio is not compatible with this 
terminal/configuration. 
Outdoor Unit 3.3V Error  The modem internal power supply is lower than the required 
3.3 VDC.  
 
 
7.11 System 
Log 
Messages 
 
Table 40: Troubleshooting - Event Log Messages 
Log Message 
Description 
Access Address : 0x%08x 
This message is displayed only after a watchdog reset 
occurs. It provides information about the software 
exception that caused the watchdog. 
Air Interface is Disabled 
The RF interface has been disabled by the user. 
Air Interface is Enabled 
The RF interface has been enabled by the user. 
Another Upgrade operation 
is currently running. Skip 
SNMP[CLI,WEB] upgrade 
The user has tried to initiate an upgrade while another 
upgrade is already in progress. The command has been 
ignored.