Page 29 of 117
Reset Switch
The Reset button is recessed in the front panel of the terminal. To operate the switch,
use a small narrow object (i.e., paper clip) to depress the switch.
use a small narrow object (i.e., paper clip) to depress the switch.
Table 13: System - Front Panel Reset Switch
Operation
Result
Depress switch
less than 5
seconds
less than 5
seconds
Short-reset. A short-reset is equivalent to cycling the
terminal power off/on. Statistics counters are reset.
terminal power off/on. Statistics counters are reset.
Depress switch
longer than 5
seconds
longer than 5
seconds
Long-reset. A long-reset sets the IP address and
password to the factory defaults. Refer to Troubleshooting
section.
password to the factory defaults. Refer to Troubleshooting
section.
3.1.6 Grounding
Connection
A ground terminal is located on the rear of the terminal. Correct grounding is very
important for safe operation of wireless equipment.
important for safe operation of wireless equipment.
3.1.7 Console
Port
The console port requires a crossover (null modem) cable to connect directly to a PC
serial port emulating a VT-52 or VT-100 terminal. The following table lists the default
settings for the Console port:
serial port emulating a VT-52 or VT-100 terminal. The following table lists the default
settings for the Console port:
Table 14: System - Console Port Default Settings
Baud 57,600
Data Bits
8
Flow Control
None
Parity None
Stop Bits
1
The following table lists the Console port pinout and associated signals.
Table 15: System - Console Port (RS-232) Pinout
Pin
Name
RS232
V.24
Description
2 RXD
BB
104
Receive
Data
3 TXD
BA
103
Transmit
Data
5
GND
AB
102
System Ground
Note: V.24 column is ITU-TSS V.24 circuit name.