Reset Switch 
The   Reset  button is recessed in the front panel of the terminal. To operate the switch, 
use a small narrow object (i.e., paper clip) to depress the switch. 
 
 
Table 13: System - Front Panel Reset Switch 
Operation 
Result 
Depress switch 
less than 5 
seconds 
Short-reset. A short-reset is equivalent to cycling the 
terminal power off/on. Statistics counters are reset.  
Depress switch 
longer than 5 
seconds 
Long-reset. A long-reset sets the IP address and 
password to the factory defaults. Refer to Troubleshooting 
section. 
3.1.6 Grounding 
Connection 
A ground terminal is located on the rear of the terminal. Correct grounding is very 
important for safe operation of wireless equipment. 
3.1.7 Console 
Port 
The console port requires a crossover (null modem) cable to connect directly to a PC 
serial port emulating a VT-52 or VT-100 terminal. The following table lists the default 
settings for the Console port: 
Table 14: System - Console Port Default Settings 
Baud 57,600 
Data Bits 
Flow Control 
None 
Parity None 
Stop Bits 
 
The following table lists the Console port pinout and associated signals. 
Table 15: System - Console Port (RS-232) Pinout 
Pin 
Name 
RS232 
V.24 
Description 
2 RXD 
BB 
104 
Receive 
Data 
3 TXD 
BA 
103 
Transmit 
Data 
GND  
AB 
102 
System Ground 
Note:  V.24 column is ITU-TSS V.24 circuit name.