4.1.1  Configuration Using a Web Browser 
1.  Set the IP address of your PC to the following settings: 
IP Address:  192.168.101.110 
Subnet mask:  255.255.255.0 
2.  Connect the host (laptop) computer directly to the Data port of the base station 
terminal using an RJ-45 Ethernet (straight-through) cable. 
3.  Power-on the base station terminal and restore the factory default settings by 
depressing the reset switch on the front panel for more than five (5) seconds. 
4.  Launch a Web Browser on the PC and enter the terminal IP address in the browser 
address field (192.168.101.3). The General Information screen is displayed and the 
operator can now login to the terminal. 
 
Figure 12: Web: Access - Browser Address Field 
Click on any configuration menu item to activate the login dialog screen.  
 
 
Figure 13: Web: Access - Base Station Login Screen 
Enter the default user name and password: 
 
User Name: admin 
 
Password: admin