the upgrade performed. Resetting the base station before activating a new software 
upgrade will cause the latest configuration to be loaded. 
12.  When using  local  synchronization (no  GPS  clock)  and the  Master  is  powered  off  or 
disconnected,  rebooting  the  Backup-Master  causes  it  to  enter  Slave  mode  and  it 
does  not  generate  synchronization  pulses.  The  Backup-Master  function  is  enabled 
only  when  synchronization  pulses  are  detected  from  a  Master  (Sync  out)  or  GPS 
clock  (Sync  in).  If  the  Master  will  be  out  of  service  for  an  extended  period,  it  is 
recommended to configure one of the Slave base stations to be a Master (requires a 
reboot). 
13.  Normal  classifiers  have  preference  over  pass-all  classifiers  on  the  same  priority 
level. 
8.1.2  Subscriber 
1.  When  upgrading,  do  not  reset  or  remove  power  from  the  subscriber  units 
immediately after the initial reboot. The software upgrade may require a minimum of 
two  minutes  to  complete  the  re-programming.  If  the  upgrade  process  is  interrupted 
the  subscriber  may  become  unmanageable  and  the  unit  must  be  returned  to  the 
factory for repair. 
2.  Upgrading  the  subscriber  from  v1.0.x  to  v2.0.x  using  the  subscriber  Ethernet  port 
may  result  in  the  subscriber  being  unable  to  reboot. The  previous  software  version 
can  not  be  restored.  Any  subscriber  that  fails  during  the  upgrade  process  must  be 
returned  to  the  factory  for  reprogramming.  It  is  strongly  recommended  to  use  the 
RedMAX RMS or the secondary management channel (SMC) from the base station 
(CLI over-the-air) to upgrade subscribers from v1.0.x to v2.0. BUG 2351 
3.  Loading  an  earlier  software  version  causes  the  subscriber  to  load  factory  default 
parameters (including radio frequency settings). This may cause loss of connectivity 
with  the  base  station.  Use  the  CLI  'switch'  command  to  return  to  the  previous 
software version (only while the previous version resides in the alternate non-volatile 
RAM). 
4.  If  the  BsID  table  is  not  populated,  rebooting  the  base  station  may  cause  the 
subscriber to switch to another base station and not return to original base station.  
5.  Uploading  an  invalid  binary  image  (e.g.,  base  station  binary  image)  causes  the 
subscriber to reject subsequent attempts to upload the correct binary file. Reboot the 
subscriber and upload the correct binary image file. 
6.  Uploading  the  SUO-U1-001-01-00-117.bin  binary  image  to  an  SU-I  will  cause  the 
unit  to  become  inoperable.  The  SU-I  must  be  returned  to  the  factory  for 
reprogramming. 
7.  The subscriber does not inform the user that a reboot is required before changes to 
RF parameters effective (e.g., channel, CP). 
8.  Following a power-cycle, the base station may not recognize the radio type for some 
early TB3335F7 and TB3436F7 radios. Power-cycle the system to clear the problem. 
9.  When  using  CLI  to  enter  frequency  ranges,  all  entries  must  be  manually  ordered 
from lowest (table entry 0) to highest. 
10.  Downgrading  is  possible if  the  previous  version is  still  located  in flash  RAM  (switch 
versions in the configuration screen). Downgrading from v2.0.x to v1.1.x may result 
in the subscriber being unable to reboot and the previous software version can not 
be  restored.  Any  subscriber  that  fails  during  the  downgrade  process  must  be 
returned to the factory for reprogramming. 2923