4.5.2  Software Upgrade 
Click 
Software  Upgrade
  in  the  menu  (left  side  of  screen)  to  upload  a  new  system 
software image from a remote server. The terminal contains two non-volatile RAM banks 
for storing the software. Each upload overwrites the standby (unselected) bank. 
 
Figure 34: Web: Admin Tools - Software Upgrade Screen 
Upgrading Software 
Protocol: Select the type of server: 
FTP: Use File Transfer Protocol for file upload. 
TFTP: Use Trivial File Transfer Protocol for file upload. TFTP is not available in the 
current software version.
 
Server IP Address: Enter the FTP server network address. 
User: Enter the username of a user that is defined on the FTP server and has sufficient 
access rights to the base station software image file. 
Password: Enter the password for the username entered in the User field above. 
File  Path:  Enter  the  path  and  name  of  the  system  software  image  to  upload.  It  is 
strongly  recommended  to  copy  the  binary  files  to  the  default  file  directory  for  the  FTP 
server and to specify only the file name in this field. 
Status: Monitors the software upload operation. 
Start Upgrade: Click  
Start Upgrade  
to begin the software upload. 
Active SW Selection 
Version: Select the software image to load on the next system reboot. 
Status: Monitors the system upgrade operation. 
Apply&Reset: Click   
Apply&Reset
   to save the current version selection and reboot the 
base station. 
Before Beginning the Upgrade 
Use the following procedures to upgrade the base station. 
The following items must be addressed before beginning the upgrade: