Robotron Pty Ltd G5E 用户手册

下载
页码 87
WiNRADiO G3XX VHF/UHF Receiver 
 
84 
Appendix I – S-meter Calibration 
The G3XX receiver series features a uniquely accurate and powerful S-meter. 
However, it is possible to improve this accuracy yet further, by individual 
calibration.  
The receiver S-meter calibration is done using a special S-meter Calibrator 
application, which can be downloaded from WiNRADiO Web page 
www.winradio.com/home/calibrator.htm. 
The S-meter Calibrator alters the factory-supplied default data in the receiver 
calibration file wrG3XX.cal which resides in the receiver application folder (i.e. 
typically C:/Program files/WiNRADiO/G3XX). 
The S-meter Calibrator requires the use of a precisely calibrated synthesized 
signal generator to generate calibration levels in the frequency range of 
interest. It possible to create calibration tables for as many frequency points as 
required, and interpolate between these tables to arrive at absolute calibration 
values for any arbitrary frequency the receiver is tuned to.  
The S-meter Calibrator includes special commands to create, edit and 
manipulate calibration tables, interpolate between individual calibration points 
within a particular table as well as between entire tables, view calibration 
graphs for individual frequencies, and other useful facilities.  
The S-meter Calibrator is provided as an “as is” complimentary tool for 
WiNRADiO receiver users. The calibration procedures should not be 
attempted by persons without a deeper understanding of the underlying 
concepts, as WiNRADiO can only provide a limited technical support for this 
application, and can accept no responsibility for any difficulties arising from its 
use.   
To restore the original factory calibration, simply delete the wrG3XX.cal file 
and reinstall the G3XX application.