To create a new range, click the New button. This will open a dialog box, 
where you can specify lower and upper limit frequencies of the range, the step 
size, modulation mode, squelch level, and, optionally, a description. You can 
enter as many such ranges as you like. 
 
 
When the range definition is done, close this window, then close the scanner 
settings. Then activate the Range button in the Scanning control panel: 
 
 
When you press the Scan Forward button [>>], the scanner will commence 
scanning from the start frequency of the first range. When the last frequency of 
the first range is reached, it will then continue onto the next range, etc. When it 
reaches the end of the last range, it will go back to the start of the first range 
and continue looping infinitely until a signal is found, or until manually stopped 
or paused. If you use the Scan Backward [<<] button, the process will be 
exactly reversed (i.e. starting from the top frequency of the last range and 
working its way downwards). 
 
 