Toshiba CTX IPT/DKT 用户手册

下载
页码 171
IPT2010-SDC
Local CO Line Connection
90
Strata CIX and CTX IPT/DKT Telephone     08/07
Local CO Line Circuit Quick Test
This procedure is a quick test to verify the CO Line connection and correct IPT2010-
SDC ACO operation. In normal operation the ACO indicator is dark when the ACO 
line is not in use, red when the ACO is used by another station, and green when the 
ACO is in use at this station. The ACO indictor that is lit a steady red, when the ACO 
is not in use, indicates no CO Line connection or a faulty CO Line circuit.
Note
The IPT2010-SDC does not require a LAN connection for this test. 
1. Apply power to the IPT2010-SDC (POE or local AC adapter). The ACO button 
will LED will be red.
2. Plug in the local CO Line connection. A functional line will cause the ACO 
indicator to go dark.
3. Lift the handset then, press the ACO button. Verify that the ACO indicator lights 
green and dial tone is heard.
4. Dial a local telephone number. Verify two-way speech.
5. Place the handset in the IPT2010-SDC and verify that the ACO indicator goes 
dark.