Bosch DS9370 用户手册

下载
页码 3
Region
Certification
Australia
RCM
Europe
CE
2004/108/EC EMC Directive (EMC);
2006/95/EC Low-Voltage Directive
(LVD) [DS9370][DS9371][DS9370-C]
Belgium
INCERT
B-509-0013 (DS9370 only)
INCERT
B-509-0013/b (DS9370-BEL only)
USA
UL
DS9370: ANSR: Intrusion Detection
Units (UL639), ANSR7: Intrusion Detec-
tion Units Certified for Canada (cULus)
FCC
ESV9370
Canada
IC
1249A-12073
China
CCC
DS9370-CHI: 2009031901000550
Brazil
ANATEL
Certificado Anatel 0871-03-1855
[DS9370 & DS9371]
Singapore
iDA
LPREQ-S0154-2004
Installation/configuration notes
Top View
0m
8m
0ft
2m
4m
6m
4m
2m
0m
2m
4m
6m
8m
7ft
13ft
20ft
26ft
33ft
39ft
0ft
7ft
13ft
10m
12m
10m
12m
39ft
33ft
26ft
20ft
13ft
7ft
Side View
Coverage Information
Provides 360° x 21 m (70 ft) diameter coverage when
the detector is mounted at 3.7 m to 7.6 m (12 ft to
25 ft).
Provides 360° x 15 m (50 ft) diameter coverage when
the detector is mounted at 3 m (10 ft). 12 m (40 ft)
when mounted at 2.4 m (8 ft).
Pattern consists of 69 zones in 21 barriers. Each
barrier is 11 m (35 ft) long and 1.5 m (5 ft) wide at
11 m (35 ft). The barriers are grouped into three
groups of seven barriers each. Each group has vertical
adjustment for customized coverage.
Technical specifications
Enclosure Design
Design:
Modular chassis and hinged mounting
base design provide easy access to field
setup switches and wiring.
Dimensions:
8.9 cm x 17.8 cm
(3.5 in. X 7 in.)
Material:
High impact ABS plastic enclosure
Environmental Considerations
Operating Temperature:
-40°C to +49°C (-40°F to +120°F)
For UL Certificated installations, 0°C to
+49°C (+32°F to +120°F)
Radio Frequency
Interference (RFI)
Immunity:
No alarm or setup on critical frequencies
in the range from 26 MHz to 950 MHz at
50 V/m.
DS9370-C:
Complies with Environmental Class II
(EN50130-5)
Microwave Frequency
DS9370 and DS9370-
BEL
10.525 GHz
DS9370-C
10.588 GHz
Mounting
Height Range:
3 m to 7.6 m (8 ft to 25 ft) recommended
Location:
Mounts directly to ceiling or to standard 10.2 cm
(3.5 in.) octagonal electrical box.
Outputs
Alarm
Form C reed relay rated at 3.0 W, 125 mA at 28 VDC for
resistive loads.
Tamper
Cover and ceiling tamper. Normally Closed (with cover in
place) tamper switch. Contacts rated at 28 VDC, 125 mA
maximum.
Power Requirements
Current:
19 mA standby, 39 mA in alarm.
Voltage:
9 VDC to 15 VDC
Trademarks
TriTech
®
 is a registered trademark of Bosch Security Systems, Inc. in the
United States.
2 | DS9370 Series Panoramic TriTech Detector