PVD40-600-V-C Surge Diverter 
 
Class II SPD arrester in accordance with IEC 
61643-1:2005. Compliance to UL1449 ed.3. 
 
600vdc Surge Protection for PV installations 
FEATURES 
• 
2 mode protection +ve - Earth, -ve - Earth 
• 
Compact solution for solar inverter protection 
• 
2 pole wide Din 43880 form factor 
• 
Replaceable plug in protection module 
• 
Includes floating-contact alarm output 
• 
Available in a range of DC voltages to 1000vdc. 
 
Applications 
• 
Grid inter active inverters 
• 
Standby inverters 
 
 
FUNCTIONAL DESCRIPTION  
The PVD40-600-V-C is designed to protect 
photovoltaic solar panel inverters from harmful 
transients by diverting excess energy to earth from 
+ve and –ve conductors to earth.   

This model (PVD40-600-V-C) is designed for 550-
600vdc systems. If your power system is a 
different voltage, this model is NOT suitable
.  
 
Please contact your supplier for a suitable model to 
suit your application. 
 
OPERATION 
The operational status of the unit is shown by a flag 
indicator on the front of the unit. In normal operation, 
the flag is green. If the unit becomes damaged, the 
flag changes to red, indicating that replacement is 
necessary. A contact alarm output is fitted to the 
base of unit and will change over if the unit is faulty. 
 
WARRANTY  
Eaton warrants this unit against faulty parts and 
workmanship for a period of 12 months from the date 
of purchase. If this product fails to operate correctly, 
please contact your Eaton representative. This 
warranty doesn’t cover neglect or intentional misuse. 
As this product is intended for use in electrically 
harsh environments no claim is made of suitability for 
purpose. This unit is designed to reduce the 
likelihood of damage. Please also note that an 
excessive surge, such as from a direct lightning strike 
to the site or a power system fault, may cause 
damage to the unit and render it inoperable. A unit 
that has been damaged in this way is not 
warrantable. 
 
 
 
 
For installation details,  
See over page. 
SPECIFICATIONS 
Manufacturers name and model 
Eaton PVD40-600-V-C 
Method of mounting 
Din rail mount 
Input voltage 
550 - 600VDC 
Maximum continuous operating 
voltage - MCOV 
620VDC 
Service type 
+VE – E , -VE - E 
Test classification  
Class II 
Supply current 
<10mA 
Initial clamp voltage  
 620VDC 
Maximum rated surge current - 
Ismax 8/20us   
 
40kA   
Nominal surge current –  
Inom 8/20us  
 
20kA 
Residual voltage (Vpl) @ Inom 
20kA, 8/20uS  at terminals 
2.0kV 
Nominal surge lifetime (In)  
20kA (8/20uS), 20 times 
Internal protection 
MOV thermal disconnect 
device. 
External disconnector  
 ( if required ) 
Gg/Gl HRC fuses,  125A 
maximum. 
Terminations 
Main terminals multi strand 
25mm
2   
Alarm terminals 1.5mm
2
Alarms/indicators 
Flag indicator,  alarm relay  
contact 250VAC/24VDC, 2A 
Location Category 
Indoor 
Enclosure rating 
IP20 
Applicable standards. 
IEC61643-1:2005, UL1449 
ed.3  
Dimensions 
90mm (H) x 36mm (W) x 
68mm (D). excluding alarm 
connector 
Weight 
180g 
Environment 
-10 to 60C, 0-90%RH 
Warranty 
12 months, workmanship 