Intel SSD DC S3500 800GB SSDSC1NB800G4 用户手册
产品代码
SSDSC1NB800G4
Intel® Solid-State Drive DC S3500
Product Specification
April 2013
10
Order Number: 328860-001US
Table 11.
Power Consumption for 1.8-inch Form Factor
Specification
1
Unit
Intel SSD DC S3500
80 GB
240 GB
400 GB
800 GB
Active Write - RMS Average @ 3.3V
W
2.0
3.5
4.5
5.2
Active Write - RMS Burst @ 3.3V
W
2.2
3.8
5.0
7.5
Idle @ 3.3V
W
0.6
0.6
0.6
0.6
Notes:
1.
The workload equates 128 KB (131,072 bytes) Queue Depth equal to 32 sequential writes. Root Mean Squared (RMS) power
is measured using scope trigger over a 100 ms sample period.
is measured using scope trigger over a 100 ms sample period.
2.4
Environmental Conditions
Table 12.
Temperature, Shock, Vibration
Temperature
Range
Case Temperature
Operating
Non-operating
1
0 – 70
o
C
-55 – 95
o
C
Temperature Gradient
2
Operating
Non-operating
30
o
C/hr (Typical)
30
o
C/hr (Typical)
Humidity
Operating
Non-operating
5 – 95 %
5 – 95 %
5 – 95 %
Shock and Vibration
Range
Shock
3
Operating
Non-operating
1,000 G (Max) at 0.5 msec
1,000 G (Max) at 0.5 msec
1,000 G (Max) at 0.5 msec
Vibration
4
Operating
Non-operating
2.17 G
RMS
(5-700 Hz) Max
3.13 G
RMS
(5-800 Hz) Max
Notes:
1. Please contact your Intel representative for details on the non-operating temperature range.
2. Temperature gradient measured without condensation.
3. Shock specifications assume the SSD is mounted securely with the input vibration applied to the drive-mounting screws. Stimulus
1. Please contact your Intel representative for details on the non-operating temperature range.
2. Temperature gradient measured without condensation.
3. Shock specifications assume the SSD is mounted securely with the input vibration applied to the drive-mounting screws. Stimulus
may be applied in the X, Y or Z axis. Shock specification is measured using Root Mean Squared (RMS) value.
3.
Vibration specifications assume the SSD is mounted securely with the input vibration applied to the drive-mounting screws.
Stimulus may be applied in the X, Y or Z axis. Vibration specification is measured using RMS value.
Stimulus may be applied in the X, Y or Z axis. Vibration specification is measured using RMS value.