Intel DC P3600 SSDPEDME016T410 用户手册

产品代码
SSDPEDME016T410
下载
页码 43
 
 
Intel
®
 Solid-State Drive DC P3600 Series 
 
October 2014 
 
 
Product Specification 
330569-004US 
 
27 
Table 19:  Additional SMART Attributes (Log Identifier CAh) 
Byte 
# of Bytes 
Attribute 
Description 
1 
AB (Program Fail Count) 
Raw value: shows total count of 
program fails. 
Normalized value: beginning at 100, 
shows the percent remaining of 
allowable program fails. 
3 
1 
Normalized Value 
5 
6 
Current Raw Value 
12 
1 
AC (Erase Fail Count) 
Raw value: shows total count of erase 
fails. 
Normalized value: beginning at 100, 
shows the percent remaining of 
allowable erase fails. 
15 
1 
Normalized Value 
17 
6 
Current Raw Value 
24 
1 
AD (Wear Leveling Count) 
Raw value: 
Bytes 1-0: Min. erase cycle 
Bytes 3-2: Max. erase cycle 
Bytes 5-4: Avg. erase cycles 
Normalized value: decrements from 
100 to 0. 
27 
1 
Normalized Value 
29 
6 
Current Raw Value 
36 
1 
B8 (End to End Error Detection Count) 
Raw value: reports number of End-to-
End detected and corrected errors by 
hardware. 
Normalized value: always 100. 
39 
1 
Normalized Value 
41 
6 
Current Raw Value 
48 
1 
C7 (CRC Error Count) 
Raw value: shows total number of 
encountered SATA interface cyclic 
redundancy check (CRC) errors. 
Normalized value: always 100. 
51 
1 
Normalized Value 
53 
6 
Current Raw Value 
60 
1 
E2 (Timed Workload, Media Wear) 
Raw value: measures the wear seen by 
the SSD (since reset of the workload 
timer, attribute E4h), as a percentage of 
the maximum rated cycles. Divide the 
raw value by 1024 to derive the 
percentage with 3 decimal points. 
Normalized value: always 100. 
63 
1 
Normalized Value 
65 
6 
Current Raw Value 
72 
1 
E3 (Timed Workload, Host Reads %) 
Raw value: shows the percentage of I/O 
operations that are read operations 
(since reset of the workload timer, 
attribute E4h). Reported as integer 
percentage from 0 to 100. 
Normalized value: always 100. 
75 
1 
Normalized Value 
77 
6 
Current Raw Value 
84 
1 
E4 (Timed Workload, Timer) 
Raw value: measures the elapsed time 
(number of minutes since starting this 
workload timer). 
Normalized value: always 100. 
87 
1 
Normalized Value 
89 
6 
Current Raw Value 
96 
1 
EA (Thermal Throttle Status) 
Raw value: reports Percent Throttle 
Status and Count of 
events 
Byte 0: Throttle status reported as 
integer percentage. 
Bytes 1-4: Throttling event count. 
Number of times thermal throttle has 
activated. Preserved over power cycles. 
Byte 5: Reserved. 
Normalized value: always 100. 
99 
Normalized Value 
101 
Current Raw Value