SPECIFICATIONS AND ORDERING INFORMATION
for operation as a differential comparator or applied 
internally as a true differential offset voltage.  
The PVG is also available for external use through a  
rear panel connector.
The DA1855A operates from 90 to 250 VAC line  
without line switching. High-performance differential 
probes such as the DXC100 ÷10/÷100 high CMRR  
probes are recommended.
Overdrive Recovery
With a ÷100 probe, the DA1855A settles to within  
100 mV referred to input, from a 400 V input signal  
within 100 ns. With attenuating probes, this allows  
the in circuit measurement of dynamic saturation in switch 
mode power converter switching devices.
Comparator Mode
The DA1855A becomes a differential comparator when the 
internal PVG output is selected as the amplifier’s inverting 
(-) input. In this mode, the DA1855A can be used to very 
accurately measure relatively small signals that are riding 
on large AC or DC components. Due to the precision of 
the voltage gener ator, an oscilloscope, when used with the 
DA1855A, can make voltage measurements that are much 
more accurate than the oscilloscope is capable of by itself. 
The output of the PVG is available for external use via a 
rear panel connector.
True Differential Offset Mode
The DA1855A has built-in Precision Voltage Generator 
can be used to generate a true differential offset while still 
allowing both inputs to be used as differential inputs. The 
offset range can be as high as ±50,000 divisions and the 
generator has 5 1/2 digit resolution. This mode facilitates 
making measurements such as changes to a transistor’s 
base to emitter voltage caused by variations in temperature 
and/or current. Used in this mode, the voltage generator 
can be set to a value that will zero out the static value 
of the junction’s on voltage. The DA1855A’s differential 
measurement capability will reject any dynamic signal 
common to both sides of the junction, and the oscilloscope 
is left to measure only the changes in the junction voltage.
Autobalance
Each time either gain setting button is pressed, the 
DA1855A automatically adjusts the amplifier’s DC balance.
Specifications
Main Specifications
Bandwidth  
> 100 MHz
Electrical Characteristics
Rise time (typical)  
< 3.5 ns
Ordering Information
Product Description 
Product Code
Differential Amplifiers
1 Ch, 100 MHz Differential Amplifier  
DA1855A 
with Precision Voltage Source
÷100 or ÷10 Selectable, 250 MHz  
DXC100A* 
Passive Differential Probe Pair
÷1, 50 MHz Passive Differential Probe Pair 
DXC200*
÷100, 250 MHz 2.5kv, High Voltage Probe Pair 
DXC-5100* 
(requires DA101 for full performance)
Ordering Information (cont’d)
 
Product Description 
Product Code
÷10 1 M
Ω 
Passive Attenuator for DXC Series Probes 
DA101*
2 Ch,100 MHz Differential Amplifier  DA1855A-PR2 
with Precision Voltage Source
DA1855A with Rackmount 
DA1855A-RM
DA1855A with Rackmount DA1855A-PR2-RM 
(must be ordered at time of purchase, no retrofit)
*Must be used with DA Series Differential Amplifiers
Customer Service
Teledyne LeCroy oscilloscopes and probes are designed, built, and tested 
to ensure high reliability. In the unlikely event you experience difficulties, 
our digital oscilloscopes are fully warranted for three years and our probes 
are warranted for one year.
This warranty includes: 
 No charge for return shipping 
 Long-term 7-year support  
 Upgrade to latest software at no charge
© 2010 by Teledyne LeCroy, Inc. All rights reserved. Specifications, prices, availability, and delivery subject to change 
without notice. Product or brand names are trademarks or requested trademarks of their respective holders.
DA1855A-DS-01nov13
1-800-5-LeCroy 
teledynelecroy.com
Local sales offices are located throughout the world.
Visit our website to find the most convenient location.