8. Mode Selector Switch Functions 
The mode selection switch is at the front of the alarm system.
Use the mode selection switch to determine the three different operating modes.
OFF:
The complete alarm system is switched off. The door bell
function is exempted from this.
HOME: The alarm system is switched on and the exit delay starts
(duration = 60 seconds). After the end of the exit delay, only
alarm zone 1 
is armed. 
AWAY: The alarm system is switched on and the exit delay starts
(duration = 60 seconds). After the end of the exit delay, both
alarm zones 
are armed.
During the exit delay, the status LED “EXIT” flashes quickly. After the end of the exit
delay, there is a short signal sound (depending on the position of jumper B). When
the alarm system is armed, the status LED “EXIT” flashes slowly
9. Jumper Functions
The jumpers are on the PCB to the right of the connection terminal. 
Jumper 1 (internal signalling device)
ACTIVATED
In case of an alarm, an acoustic alarm is triggered
by the internal signalling device.
DEACTIVATED In case of an alarm, no acoustic alarm is triggered
by the internal signalling device. This does not app-
ly to the internal door bell and the signal sounds.
A
1 2
A
1 2
HOME AWAY
OFF
HOME AWAY
OFF
HOME AWAY
OFF
33