Galil DMC-2X00 用户手册
DMC-2X00
Chapter 9 Troubleshooting
y 131
Communication
SYMPTOM CAUSE
REMEDY
Using terminal emulator, cannot
communicate with controller.
communicate with controller.
Selected comm. port incorrect
Try another comport
Same as above
Selected baud rate incorrect
Check to be sure that baud rate
same as dip switch settings on
controller, change as necessary.
same as dip switch settings on
controller, change as necessary.
Stability
SYMPTOM CAUSE REMEDY
Motor runs away when the loop is
closed.
closed.
Wrong feedback polarity.
Invert the polarity of the loop by
inverting the motor leads (brush type)
or the encoder.
inverting the motor leads (brush type)
or the encoder.
Motor oscillates.
Too high gain or too little
damping.
damping.
Decrease KI and KP. Increase KD.
Operation
SYMPTOM CAUSE
REMEDY
Controller rejects command.
Responded with a ?
Responded with a ?
Anything.
Interrogate the cause with TC or
TC1.
TC1.
Motor does not complete move.
Noise on limit switches stops the
motor.
motor.
To verify cause, check the stop
code (SC). If caused by limit
switch noise, reduce noise.
code (SC). If caused by limit
switch noise, reduce noise.
During a periodic operation, motor
drifts slowly.
drifts slowly.
Encoder noise
Interrogate the position
periodically. If controller states
that the position is the same at
different locations it implies
encoder noise. Reduce noise. Use
differential encoder inputs.
periodically. If controller states
that the position is the same at
different locations it implies
encoder noise. Reduce noise. Use
differential encoder inputs.
Same as above.
Programming error.
Avoid resetting position error at
end of move with SH command.
end of move with SH command.