Galil DMC-2X00 用户手册

下载
页码 267
140  
  Chapter 10 Theory of Operation 
DMC-2X00  
For example, if the filter parameters of the DMC-2x00 are 
 
KP = 4 
 KD 
36 
 
KI = 2 
 PL 
0.75 
 
T = 0.001 s 
the digital filter coefficients are 
 K 
160 
 A 
0.9 
 
C = 1 
 
a = 250 rad/s 
and the equivalent continuous filter, G(s), is 
 
G(s) = [16 + 0.144s + 1000/s} 
∗ 250/ (s+250) 
 
The notch filter has two complex zeros, Z and z, and two complex poles, P and p. 
The effect of the notch filter is to cancel the resonance affect by placing the complex zeros on top of 
the resonance poles.  The notch poles, P and p, are programmable and are selected to have sufficient 
damping.  It is best to select the notch parameters by the frequency terms.  The poles and zeros have a 
frequency in Hz, selected by the command NF.  The real part of the poles is set by NB and the real part 
of the zeros is set by NZ. 
The simplest procedure for setting the notch filter is to identify the resonance frequency and set NF to 
the same value.  Set NB to about one half of NF and set NZ to a low value between zero and 5. 
ZOH 
The ZOH, or zero-order-hold, represents the effect of the sampling process, where the motor command 
is updated once per sampling period.  The effect of the ZOH can be modeled by the transfer function 
 H(s) 
1/(1+sT/2) 
If the sampling period is T = 0.001, for example, H(s) becomes: 
 H(s) 
2000/(s+2000) 
However, in most applications, H(s) may be approximated as one. 
This completes the modeling of the system elements.  Next, we discuss the system analysis.