Galil DMC-2X00 用户手册

下载
页码 267
DMC-2X00 
Appendices  
y 157  
Pin-Out Description for DMC-2x00 
Outputs 
Analog Motor Command 
+/- 10 volt range signal for driving amplifier.  In servo mode, 
motor command output is updated at the controller sample rate.  In 
the motor off mode, this output is held at the OF command level. 
Amp Enable 
Signal to disable and enable an amplifier.  Amp Enable goes low 
on Abort and OE1. 
PWM/STEP OUT 
PWM/STEP OUT is used for directly driving power bridges for 
DC servo motors or for driving step motor amplifiers.  For servo 
motors:  If you are using a conventional amplifier that accepts a 
+/-10 volt analog signal, this pin is not used and should be left 
open.  The PWM output is available in two formats:  Inverter and 
Sign Magnitude.  In the Inverter mode, the PWM signal is .2% 
duty cycle for full negative voltage, 50% for 0 voltage and 99.8% 
for full positive voltage (25kHz switching frequency).  In the Sign 
Magnitude Mode (Jumper SM), the PWM signal is 0% for 0 
voltage, 99.6% for full voltage and the sign of the Motor 
Command is available at the sign output (50kHz switching 
frequency). 
PWM/STEP OUT 
For step motors:  The STEP OUT pin produces a series of pulses 
for input to a step motor driver.  The pulses may either be low or 
high.  The pulse width is 50%.  Upon Reset, the output will be low 
if the SM jumper is on.  If the SM jumper is not on, the output will 
be tristate. 
Sign/Direction 
Used with PWM signal to give the sign of the motor command for 
servo amplifiers or direction for step motors. 
Error 
The signal goes low when the position error on any axis exceeds 
the value specified by the error limit command, ER. 
Output 1-Output 8 
Output 9-Output 16 
(DMC-2x50 thru 2x80 
 
These 8 TTL outputs are uncommitted and may be designated by 
the user to toggle relays and trigger external events.  The output 
lines are toggled by Set Bit, SB, and Clear Bit, CB, instructions.  
The OP instruction is used to define the state of all the bits of the 
Output port. 
Inputs  
Encoder, A+, B+ 
Position feedback from incremental encoder with two channels in 
quadrature, CHA and CHB.  The encoder may be analog or TTL.  
Any resolution encoder may be used as long as the maximum 
frequency does not exceed 12,000,000 quadrature states/sec.  The 
controller performs quadrature decoding of the encoder signals 
resulting in a resolution of quadrature counts (4 x encoder cycles).  
NOTE:  Encoders that produce outputs in the format of pulses and 
direction may also be used by inputting the pulses into CHA and 
direction into Channel B and using the CE command to configure 
this mode.