Galil DMC-2X00 用户手册

下载
页码 267
4  
  Chapter 4 Communication 
DMC-2X00  
(Configure Communication) at port 2.  The command is in the format of: 
 CC 
m,n,r,p 
where m sets the baud rate, n sets for either handshake or non-handshake mode, r sets for general port 
or the auxiliary port, and p turns echo on or off. 
m - Baud Rate - 300,1200,4800,9600,19200,38400  
n - Handshake - 0=No; 1=Yes  
r - Mode - 0=General Port; 1=Daisy-chain  
p - Echo - 0=Off; 1=On; Valid only if r=0  
Note, for the handshake of the auxiliary port, the roles for the RTS and CTS lines are reversed. 
Example: 
CC 1200,0,0,1  
 
Configure auxiliary communication port for 1200  baud, no handshake, general 
port mode and echo turned on.  
Daisy-Chaining (DMC-2000 only) 
 
Up to eight DMC-2000 controllers may be connected in a daisy-chain allowing for multiple controllers 
to be commanded from a single serial port.  One DMC-2000 is connected to the host terminal via the 
RS232 at port 1 or the main port.  Port 2 or the auxiliary port of that DMC-2000 is then brought into 
port 1 of the next DMC-2000, and so on.  The address of each DMC-2000 is configured by setting the 
three address dipswitches (A0, A1, A2) located on the front of the controller. 
When connecting multiple controllers in a daisy-chain, the cable between controllers should be female 
on both ends with all wires connected straight through. 
ADR1 represents the 2
bit, ADR2 represents 2
1
 bit, and ADR4 represents 2
2
 bit of the address.  The 
eight possible addresses, 0 through 7, are set as follows: 
 
A2  
A1  
A0  
ADDRESS  
OFF OFF OFF 
OFF OFF  ON 
OFF ON OFF 
OFF ON  ON 
ON OFF OFF 
ON OFF ON 
ON ON OFF 
ON ON ON 
To communicate with any one of the DMC-2000 units, give the command “%A”, where A is the 
address of the board.  All instructions following this command will be sent only to the board with that 
address.  Only when a new %A command is given will the instruction be sent to another board.  The 
only exception is "!" command.  To talk to all the DMC-2000 boards in the daisy-chain at one time, 
insert the character "!" before the software command.  All boards receive the command, but only 
address 0 will echo. 
NOTE:  The CC command must be specified to configure the port P2 of each unit.