Bosch Appliances Automobile Electronics LBB 4188 用户手册

下载
页码 20
DCN Next Generation Automatic Camera Control 
en | 8 
 
3
  Using Automatic Camera 
Control 
3.1
  The camera installation main window 
The Camera Installation main window is used to 
assign fixed cameras and camera positions (on 
preposition cameras) to DCN Next Generation units. 
 
There are two main types of camera recognized by 
the Automatic Camera Control software. Fixed 
cameras are positioned before the conference begins, 
and they remain in the same position during the 
conference. Dome cameras can adjust their position 
automatically in response to conference activity. For 
example, a dome camera normally has several 
prepositions, determined during configuration, each 
covering a different delegate or group of delegates. 
The camera will automatically change position to 
cover the delegate who is speaking. The Camera 
Installation window at startup is shown below. 
 
Figure 3 The Camera Installation window (at startup) 
 
 i 
   Note 
The System Installation file is required for using 
Automatic Camera Control with a software-
controlled DCN Next Generation system. This 
file is loaded from the Startup screen. In the 
example used in this manual, 10 seats have 
been assigned in the System Installation file. 
 
 i 
   Note 
In the stand-alone version of the software, 
‘seats’ are referred to as ‘units’. 
 
The Camera Installation window contains the 
following elements: 
• 
Start/Stop push button. This is used to enter and 
exit Installation mode. 
• 
Camera specification edit fields for entering 
camera number, camera ID, and the type of 
camera (fixed or preposition)  
 
When installation mode is entered (by pressing the 
Start push button) for the first time i.e. when no 
cameras have yet been assigned to seat numbers, or 
when camera 1 is selected from the ‘Assignments’ list 
the installation window appears as follows: 
 
Figure 4 The Camera Installation window 
 
 i 
   Note 
If a camera with prepositions (such as a dome 
camera) is selected, the number of 
prepositions available, and the selected 
preposition is also entered in this area. 
 
• 
‘Selected preposition:’ edit field (only displayed if 
the camera is a preposition type) 
• 
Seat (or unit) edit fields for selecting a seat (or 
unit) number and entering one or two lines of 
seat/unit text 
• 
‘Insert’ button for entering the camera and unit 
assignments specified (it then appears in the 
‘Assignments’ list on the right side of the main 
window) 
• 
‘Delete’ button for removing camera and unit 
assignments from the ‘Assignments’ list. 
• 
‘Assignments’ list for displaying assigned camera 
data. 
 
 
 
 
 
 
 
 
 
 
 
Bosch Security Systems B.V. | 2005 January | 9922 141 70491