SERVICE (cont.)
Safety Overflow Switch
Location:
The safety overflow switch is located inside the rear of 
the dispenser inside the copper overflow cup.
For testing or removal of the safety overflow switch, 
access may also be needed by removing the two screws 
attaching the electronic control assembly to its mount-
ing bracket.
Test Procedure:
1.  Once voltage is verified at the power source, check 
for continuity across the safety overflow switch 
red wires only until the plastic float is raised and 
check that continuity returns when the plastic float 
is again lowered.
If continuity is present as described, reconnect each 
of the red wires to the black wires, the safety overflow 
switch is operating properly.
If continuity is not present as described, replace the 
safety overflow switch.
FIG. 13a SAFETY OVERFLOW SWITCH
FIG. 13c SAFETY OVERFLOW WIRING
This
 eq
uipm
ent
 is to 
be 
ins
talle
d to
com
ply wi
th the
 Bas
ic P
lum
bing
 Co
de 
of
the 
Bui
lding
 Of
ficia
ls a
nd 
Cod
e
Adm
inistr
ators
 Inte
rna
tion
al, In
c. (B
OC
A)
an
d th
e Food
 Ser
vice
 Sani
tation
 Ma
nua
l
of th
e Food
 and 
Dr
ug 
Adm
inistr
atio
n (F
DA
).
RED to BLK Wire from 
Terminal Block
RED to BLK Wire from Elec-
tronic Control #3
P4093
P1777
Removal and Replacement:
1.  Disconnect the black wires from the safety overflow 
switch.
2.  Remove the nut beneath the copper overflow cup.
3.  Remove the entire switch assembly from the cup.
4.  Place the new switch assembly into the cup, wires 
first. Make sure that a gasket is in place around the 
threaded switch stem.
NOTE - The magnets must be at the top of the float and 
there must be NO stainless steel washers installed for 
the safety overflow switch to operate properly.
5.  Install the nut beneath the copper overflow cup.  
Be sure not to overtighten.
6.  Reconnect the wires, FIG. 6.
P1993
FIG. 13b OVERFLOW PROTECTION  SWITCH
42311 071310
H 10