2.4
AM713 Rear Panel
Figure 2-2 AM713 Rear Panel
Input Voltage Selector: This red switch allows the unit to operate in either 110/115 
VAC or 220/230/240 VAC environments. A fuse must also be changed for 220/230/240 
VAC operation (see page 6). Units are shipped set and fused for 110/115 VAC. 
Power Connector (IEC) and Fuse Tray: The IEC power connector accepts standard 
IEC power cords. The fuse tray contains both the active fuse and a spare fuse for 220/
230/240 VAC operation. See page 6 for instructions on how to change the fuse for 220/
230/240 VAC operation. 
Analog Inputs (female XLR): 24 balanced, analog inputs on XLR connectors. Input 
sensitivity is set from the front panel.
Auxiliary Analog Inputs (female XLR): Two balanced analog inputs on XLR connectors. 
Input sensitivity is set from the front panel.
AES/EBU Digital Input (female XLR): Stereo AES/EBU digital input on one XLR 
connector. Functions in parallel with the auxiliary S/PDIF input and the two inputs 
should not be used simultaneously.
S/PDIF Digital Input (RCA): Stereo S/PDIF digital input on one RCA connector. 
Functions in parallel with the auxiliary AES/EBU input and the two inputs should not 
be used simultaneously.
AES Sync In (female XLR): Master clock input for the converter when using AES as 
Sample Rate Source.
AES Sync Thru (male XLR): Outputs the same signal connected to AES Sync In.
Word In (BNC): Master clock input for the converter when using Word Clock as 
Sample Rate Source.
Word Out (BNC): Outputs a Word clock signal synchronized to the Sample Rate 
Source. In the presence of an external Word clock input, this connector provides a 
regenerated version of that input signal. Without an external sample rate source, this 
connector outputs the internally generated clock signal.