Euphonix AM713 用户手册
Euphonix MADI Converters Operation Manual
DM714 and MD704 Converters
26
3.5
MD704 Rear Panel
Figure 3-3 MD704 Rear Panel
Input Voltage Selector: This red switch sets the unit to either 110/115 VAC or 220/
230/240 VAC environments. A fuse must also be changed for 220/230/240 VAC oper-
ation (see page 6). Units are shipped set and fused for 110/115 VAC.
230/240 VAC environments. A fuse must also be changed for 220/230/240 VAC oper-
ation (see page 6). Units are shipped set and fused for 110/115 VAC.
Power Connector (IEC) and Fuse Tray: The IEC power connector accepts standard
IEC power cords. The fuse tray contains both the active and spare fuses. See page 6 to
learn how to change the fuse for 220/230/240 VAC operation.
IEC power cords. The fuse tray contains both the active and spare fuses. See page 6 to
learn how to change the fuse for 220/230/240 VAC operation.
AES/EBU Digital Outputs (female XLR): 12 AES/EBU stereo outputs.
Parallel AES/EBU Digital Outputs (female DB25): Three 8-channel digital connectors
function in parallel with XLR digital outputs and the two outputs should not be used
simultaneously. See Figure 3-5 on page 33 for pinout diagram.
function in parallel with XLR digital outputs and the two outputs should not be used
simultaneously. See Figure 3-5 on page 33 for pinout diagram.
Auxiliary Analog Outputs (male XLR): Two balanced analog outputs on XLR con-
nectors. Output level can is set from the front panel.
nectors. Output level can is set from the front panel.
AES/EBU Digital Outputs (male XLR): Stereo AES/EBU digital outputs on one XLR
connector. Functions in parallel with the auxiliary S/PDIF output and the two outputs
should not be used simultaneously.
connector. Functions in parallel with the auxiliary S/PDIF output and the two outputs
should not be used simultaneously.
S/PDIF Digital Outputs (RCA): Stereo S/PDIF digital output on one RCA connector.
Functions in parallel with the auxiliary AES/EBU output and the two outputs should
not be used simultaneously.
Functions in parallel with the auxiliary AES/EBU output and the two outputs should
not be used simultaneously.
AES Sync In (female XLR): Master clock input for the converter when using AES as
the Sample Rate Source.
the Sample Rate Source.
AES Sync Thru (male XLR): Outputs the same signal connected to AES Sync In.
Word In (BNC): Master clock input for the converter when using Word Clock as
Sample Rate Source.
Sample Rate Source.
Word Out (BNC): Outputs a Word Clock signal synchronized to the Sample Rate
Source. In the presence of an external Word clock input, this connector provides a re-
generated version of the input signal. Without an external sample rate source, this
connector outputs an internally generated clock signal.
Source. In the presence of an external Word clock input, this connector provides a re-
generated version of the input signal. Without an external sample rate source, this
connector outputs an internally generated clock signal.