LTC 8600 | LTC 8800 Series
en | 101
F.01U.127.393 | 2.0 | 2009.03
Instruction Manual
Bosch Security Systems, Inc.
Error 80 - Trunk not available 
An attempt was made to access a remote camera connected to a satellite sys-
tem, but no unused trunk lines are currently available. Depending on system 
configuration and certain user options, the operator's monitor may automati-
cally switch to the default camera programmed into the Start-up column of the 
Monitor Table when this error occurs.
Error 81 - Satellite Trunk Seized 
The camera currently viewed has changed because an operator with a higher 
priority has selected a different camera that seized the trunk line from the satel-
lite. The operator's monitor will automatically be switched to the default cam-
era programmed into the Start-up column of the Monitor Table.
Error 89 - internal stack error
A stack overflow within the system has occurred. Report this to the manufac-
turer.
Error 90 - Keyboard entry undefined
The keyboard entry is not defined. Check the appropriate section of the instruc-
tion manual for the desired operation and try again.
Error 92 - Keyboard entry out of range
The data entered for a valid command was not in the range allowed by the sys-
tem. Check the appropriate section of the instruction manual for the acceptable 
ranges for the command in question and try again.
Error 94 - Keyboard entry invalid 
An invalid character has been received from the keyboard. Usually this would 
indicate a communications error. Verify that the keyboard-to-system cable is not 
producing an intermittent connection. 
Error 95 - Keyboard entry incomplete
The control sequence sent from the keyboard was incomplete. Usually this 
would indicate a communications error. Verify that the keyboard-to-system 
cable is not producing an intermittent connection.
Error 96 - * (STAR) undefined
The 
* key has been pressed, but there is no definition for this button.
Warning Messages
Hi/Low Temperature Alert
The Allegiant CPU is equipped with a temperature sensor. If the ambient CPU 
temperature drops below -10 degrees C or goes above +55°C, an on-screen 
“Temperature Alert” message will appear on the system monitors and the sys-
tem keyboards will begin to beep.