Bosch Appliances Home Security System LTC 8600 用户手册

下载
页码 126
LTC 8600 | LTC 8800 Series
en | 55
F.01U.127.393 | 2.0 | 2009.03
Instruction Manual
Bosch Security Systems, Inc.
14.2.2 Middle Data Receiver DIP Switch S2
The lower DIP switch provides certain user-selectable options. These options are as 
follows:
Switch 1 of S2
This switch is reserved and should be left 
OFF.
Switch 2 and Switch 3 of S2
Up to eight (8) system keyboards can be connected to the rear panel of the 
LTC 8802 Series Monitor Expansion Bay. DIP switches 2 and 3 determine the 
system keyboard group that can be assigned. Follow the table below to select 
the desired group.
Switch 4 and Switch 5 of S2
These switches are reserved and should always be left 
OFF.
Switch 6 of S2
When switch 6 is 
ON, the LTC 8816/00 data receiver module communicates 
with system keyboards using the newer “6 poll byte” protocol. This format is 
required to provide variable speed pan/tilt control capability for AutoDome 
equipped camera sites. If it is necessary to communicate to older system key-
boards that are only compatible with fixed speed keyboard protocols, place the 
switch in the 
OFF position.
Switch 7 of S2
This switch determines the operational mode of the LTC 8816/00 and must 
always be left 
ON. 
Switch 8 of S2
This switch determines the operational mode of the LTC 8816/00 and must 
always be left 
OFF.
14.2.3 Lower Data Receiver DIP Switch S3
The lower DIP switch does not currently provide any user-selectable options, 
and all settings should be left in their 
OFF position.
DIP Switch Number Factory Default Setting S2 DIP Switch Function
1
OFF
Reserved
2
OFF
Keyboard Group
3
ON
Keyboard Group
4
OFF
Reserved
5
OFF
Reserved
6
ON
Keyboard Mode
7
ON
Operational Mode
8
OFF
Operational Mode
Switch 2
Switch 3
Keyboard Group
Off
Off
Reserved
Off
On
Keyboards 9-16 (Default)
On
Off
Keyboards 17-24
On
On
Keyboards 25-32