14.2.2 Middle Data Receiver DIP Switch S2
The lower DIP switch provides certain user-selectable options. These options are as
follows:
follows:
•
Switch 1 of S2
This switch is reserved and should be left
OFF.
•
Switch 2 and Switch 3 of S2
Up to eight (8) system keyboards can be connected to the rear panel of the
LTC 8802 Series Monitor Expansion Bay. DIP switches 2 and 3 determine the
system keyboard group that can be assigned. Follow the table below to select
the desired group.
LTC 8802 Series Monitor Expansion Bay. DIP switches 2 and 3 determine the
system keyboard group that can be assigned. Follow the table below to select
the desired group.
•
Switch 4 and Switch 5 of S2
These switches are reserved and should always be left
OFF.
•
Switch 6 of S2
When switch 6 is
ON, the LTC 8816/00 data receiver module communicates
with system keyboards using the newer “6 poll byte” protocol. This format is
required to provide variable speed pan/tilt control capability for AutoDome
equipped camera sites. If it is necessary to communicate to older system key-
boards that are only compatible with fixed speed keyboard protocols, place the
switch in the
required to provide variable speed pan/tilt control capability for AutoDome
equipped camera sites. If it is necessary to communicate to older system key-
boards that are only compatible with fixed speed keyboard protocols, place the
switch in the
OFF position.
•
Switch 7 of S2
This switch determines the operational mode of the LTC 8816/00 and must
always be left
always be left
ON.
•
Switch 8 of S2
This switch determines the operational mode of the LTC 8816/00 and must
always be left
always be left
OFF.
14.2.3 Lower Data Receiver DIP Switch S3
•
The lower DIP switch does not currently provide any user-selectable options,
and all settings should be left in their
and all settings should be left in their
OFF position.
DIP Switch Number Factory Default Setting S2 DIP Switch Function
1
OFF
Reserved
2
OFF
Keyboard Group
3
ON
Keyboard Group
4
OFF
Reserved
5
OFF
Reserved
6
ON
Keyboard Mode
7
ON
Operational Mode
8
OFF
Operational Mode
Switch 2
Switch 3
Keyboard Group
Off
Off
Reserved
Off
On
Keyboards 9-16 (Default)
On
Off
Keyboards 17-24
On
On
Keyboards 25-32