Raymarine 150/400 用户手册

下载
页码 64
20
Type 150/400 Autopilot System: Installation Guide
Ste
p
4.2 Mount the compass
            
Fluxgate compass - orientation
CAUTION:
You must mount the fluxgate compass vertically, with the cables 
exiting at the base. 
1. Hold the compass against the mounting location.
2. Mark the four mounting holes, then remove the compass. 
3. Drill four pilot holes using a 3 mm (
1
/
8
 in) drill bit. 
4. Making sure the cable exits at the bottom of the compass, secure 
the fluxgate compass using the self-tapping screws provided 
(No 8 x 
3
/
4
 in, pan-head). 
Note: Stick the supplied warning label near to the compass, where it 
is clearly visible. 
4.3 Connect to the course computer
1. The compass is supplied with 8 m (26 ft) of cable. Route the cable 
to the course computer, taking into account the EMC installation 
guidelines (page 7).
Note: Make sure you leave some spare cable so, if necessary, you can 
re-position the compass to reduce deviation. If the standard cable is 
not long enough, your Raymarine dealer can supply a 10 m (30 ft) 
extension cable (part number: D174)
2. Connect the five cores of the cable to the FLUXGATE terminals on 
the course computer (as shown).
D5384-1
Vertical
81173_3.book  Page 20  Thursday, June 7, 2001  11:51 AM