StorageTek Host Software Component 6 用户手册

下载
页码 718
Chapter 4. Utility Functions   215
1st ed., 6/30/04 - 312579601
 
For regularly scheduled backups of HSC control data sets, do not specify the CDS 
keyword when each CDS copy is not being backed up individually in the same time 
frame. The reason for not specifying the CDS keyword is that a CDS switch(es) may 
have taken place. 
(Primary) 
specifies that the primary control data set is to be copied to the SLSBKUP data 
set. 
(Secondary) 
specifies that the secondary control data set is to be copied to the SLSBKUP 
data set. 
(STandby) 
specifies that the standby control data set is to be copied to the SLSBKUP data 
set. 
Notes: 
 1. The CDS parameter specifies the CDS currently in that position. For example, 
if the primary CDS is disabled and the secondary CDS is running as the 
primary, specify Primary (not Secondary) to back up the secondary CDS. 
 2. Using the CDS parameter is especially useful for libraries operating through a 
remote link, such as channel extenders. Should the link drop and the primary 
CDS and the secondary CDS complete processing separately, you may bypass 
the programmatic algorithm that normally determines the control data set to be 
backed up. If you know which data set (primary or secondary) had the most 
cartridge processing, then you can select that data set to be processed by the 
utility. 
OPTion 
optionally, allows you to select one of three backup options.
(Copy) 
if this parameter is specified, NO block analysis is performed. The backup is 
taken from one of the control data sets. This function is a straight copy to the 
SLSBKUP data set. /FILE SLSCOPYx statements are not required in the JCL 
for this option.
OPTion(Copy) is the default and should be used or defaulted to for 
regularly scheduled backups of the HSC control data set.
 
OPTion(Copy) determines which copy of the CDS is the most current and 
copies that CDS copy to the SLSBKUP data set. This dynamic determination of 
the current primary CDS is disabled if the CDS keyword is specified. 
(Analyze)
this option allows detailed analysis of individual blocks to occur. A reserve is 
held against the control data set until the SLSCOPY data sets are made and the 
journals are reset. An analysis is made and discrepancies are output to a 
Backup