3. Installation
RuggedCom® RuggedBackbone™
22
RX5000 Installation Guide Rev106
3.2. Power Supply Wiring And Grounding
The RuggedBackbone™ RX5000 may be ordered with dual redundant power supplies, in positions
PM1 and PM2 (see 
).  Power connections are located either on
the PM1 and PM2 module face plates or on the front panel of the RX5000. An optional chassis ground
connection is located on the front panel as pictured in 
.
Each RX5000 Power Module is equipped with a Phillips screw terminal block (
) for main
power connection.  The Phillips Screw Terminal Block has Phillips screws with compression plates,
allowing either bare wire connections or crimped terminal lugs. We recommend the use of #6 size
ring lugs to ensure secure, reliable connections under severe shock or vibration. The terminal block
has a safety cover which must be removed via two Phillips screws before connecting any wires. The
safety cover must be reattached after wiring to ensure personnel safety.
A permanently connected RuggedBackbone™ RX5000 must have a readily accessible
disconnect device incorporated external to the equipment.
The  RX5000  may  have  two  (2)  power  supplies  installed  and  be  supplied  from  multiple
power sources. Service personnel must isolate both power supplies prior to servicing.
Figure 3.12. RX5000 Power Connector
Pin
Function
Live
Ground
Neutral
Table 3.1. RX5000 Power Connector Pinout
The following sections illustrate methods of connecting power to the RuggedBackbone™ RX5000.