RTS SSA-424A 用户手册

下载
页码 22
Installation
12
2-Wire Call Signal
Call Signal Connections for Audiocom, RTS TW 
and Clear-Com
The call signals are superimposed on the audio signal, so no 
separate call signal connections are required. However, 
make sure that a call enable switch or jumper is installed for 
Clear-Com applications as shown in Figure 6 on page 11 and 
Figure 7.
Call Signal Connections for Other 2-Wire 
Communication Systems
Any other 2-wire device must be able to generate and 
receive a 20 kHz signal superimposed on the audio as 
follows:
SSA-424A Signal Specifications for balanced configuration:
SSA-424A Receive: 20 kHz ±100 Hz, 100 mV
RMS
SSA-424A Send: 20 kHz ±800 Hz, 500 mV
RMS
, ±10%
SSA-424A Signal Specifications for unbalanced 
configuration:
SSA-424A Receive: 20 kHz ±100 Hz, 100 mV
RMS
SSA-424A Send: 20 kHz ±800 Hz, 350 mV
RMS, 
±10%
FIGURE 7. Call signal connections for a 4-wire intercom system 
other than ADAM, ADAM CS and Zeus.
Balanced Audio Configuration
Pin 1
No Connection
Pin 2
Balanced 20 kHz + Input/Output
Pin 3
Balanced 20 kHz - Input/Output
Unbalanced Configuration 1
Pin 1
20 kHz Common
Pin 2
20 kHz Input/Output
Pin 3
No Connection
Unbalanced Configuration 2
Pin 1
20 kHz Common
Pin 2
No Connection
Pin 3