Features
ON/OFF Control - 
Controls power to all outlets. The switch is 
also a 15A breaker. When an overload occurs, it will automatically 
switch off. To resume operation,ensure the overload condition is 
removed and set the switch to On.
LED indicators 
– A lit Protected amber LED indicates surge 
protection is operating normally. If it is NOT lit, it may mean a 
substantial surge event has occurred and the surge protector 
should be replaced. A lit Grounded amber LED indicates the wall 
outlet is properly grounded. If it is NOT lit, it means the outlet is not 
properly grounded and another outlet should be used to ensure 
full surge protection. When both amber LEDs are lit, it indicates 
normal operation and full surge protection.
Master and Controlled by Master outlets 
– Computer 
peripherals continue to draw power when in standby mode. 
The Master and Controlled by Master outlet feature prevents 
energy draw by automatically shutting off power to up to four (4) 
peripherals when the computer goes into standby mode. 
Note: Only connect devices to the Controlled by Master outlets that are normally 
used when the master device (e.g. computer) is operating.
To use this feature, make sure the standby function on your 
computer is enabled and plug your computer into the Master 
outlet, and plug peripherals (e.g. monitor, printer, scanner, and 
speakers) into the Controlled by Master outlets.
When your computer goes into standby mode, power will be shut 
off to peripherals plugged into the Controlled by Master outlets. 
When the computer “awakens’”, the surge protector immediately 
supplies power to these peripherals.
To ensure this feature works properly, enable standby mode in 
your computer’s power management settings. For Windows, 
open the Control Panel, select Power Options, then under 
Settings for Power Schemes, select a system standby time period. 
For Macs, open System Preferences and select Energy Saver.
For Audio/Video (A/V) application: plug the primary A/V device 
(e.g. TV) into the Master outlet and plug peripherals (e.g. set-top 
box, DVD player, and amplifier) into the Controlled by Master 
outlets.
Some computers continue to consume more than 10W of 
power in standby mode. The Master outlet may not recognize 
the standby mode, and the outlets will not shut off. If this 
occurs, make sure Hibernate/ Sleep mode is also enabled on 
your computer under power management settings, or check 
with your computer’s manufacturer.
RF-AVS7ES 7-outlet surge protector
Safety information
To ensure the safety of children and to avoid electric shock and 
damage from a high-dust environment, slide the plastic outlet 
cover over outlets that are not in use.
Protecting Phone/Fax/Modem 
– To protect your equipment 
from surges along phone/fax/modem lines, plug the phone line 
from the wall outlet into the IN port and  phone/fax/modem 
line(s) into OUT port(s).
Protecting Coaxial Cable 
To protect your equipment from 
surges, connect your coax cable from wall outlet into IN coax port 
and then connect coax cable from device into  OUT coax port.
Specifications
Seven (7) outlets
One (1) AC Adapter-spaced outlet
Phone line protection: 1 in / 2 out 
Coaxial cable protection (F): 1 in / 1 out
6 ft. (1.8m) Soft-Flex™ power cord with right-angle plug
2250 Joules rating
Connected equipment warranty: $200,000
Continuous Duty Electrical Rating: 15A / 125V / 1875W
Maximum Energy Dissipation and H-N / H-G / N-G
values: 2250J / 105,000A
Maximum Spike Current and H-N / H-G value /N-G values:  
6,000V / 105,000A(H-N 45,000A) (H-G 30,000A) (N-G 30,000A)
UL Clamping Voltage: UL 1449/ 330V(L-N)400V(L-G,N-G)
Response Time: Less than 1 nanosecond
EMI/RFI Noise Filtration: 150K Hz - 100M Hz, Up to 43dB
One Year Limited Warranty
Visit www.rocketfishproducts.com for details 
RoHS compliant                                
ENGLISH  09-0687
CAUTION: Risk of electric shock. Use only in dry locations and only indoors. 
DO NOT plug into another relocatable power tap. DO NOT “daisy chain” surge 
protectors. DO NOT use with any aquarium equipment. DO NOT use if properly 
grounded outlets are not available. DO NOT install this device if there is not at least 
30 feet (10 meters) or more of wire between the electrical outlet and electrical 
service panel.
Coaxial cable 
protection
Phone line 
protection
Master/AC 
adapter-spaced 
outlet
4 Master-Controlled outlets
2 always-on outlets
Protective outlet covers
6 ft (1.8m) Soft-Flex