KVH Industries TracPhone V7 用户手册

下载
页码 30
15
Follow these steps to connect power to the 
TracPhone V7 system.
a. Before you begin, disconnect vessel power.
b. Be sure the vessel is properly grounded in 
accordance with marine standards. 
c. Connect the control unit and modem to the 
supplied AC power strip (see Figure 31 and 
Figure 32). Use the special adapter cables 
provided in the kitpack.
d. Connect the appropriate power cord (US or 
European) to the power strip. 
e. Connect the supplied AC/DC adapters to the 
MTA, router, and remote service & support 
module. Then plug the adapter cables into 
the vessel’s AC power supply.
f. Strain-relieve all wires at the back of the 
control unit and modem by securing them to 
the attached strain-relief bracket(s). Use the 
tie-wraps supplied in the kitpack. Be sure to 
leave enough slack in the cables for easy 
serviceability. 
g. Plug the power strip into the vessel’s 115 or 
230 VAC power supply.
CAUTION
For your own safety, disconnect vessel power 
and make sure the circuit is dead before you 
connect any power cables. 
Vessel AC Power
(115 or 230 VAC)
J1
AC PWR
J3
Rx RF
J2
Tx RF
J4
ACU
J5
CONSOLE
J6
BUC PWR
J8
USER
ENET
J7
ACU
ENET
NO OPERATOR
SERVICEABLE
PARTS INSIDE,
DO NOT OPEN
CAUTION
MODEL: VMBR-1510 ArcLight
PART: 1234567 REV XXX
SERIAL: XX-XXXXXX
CAGE CODE: 12345
Antenna On/Off
Audio
SIM
Power
Power
Strip 
AC/DC
Adapter
12V DC
RSTR
WAN
LAN
PHONE 2
PHONE 1
Control Unit
Modem
Remote Service Module
MTA
AC/DC
Adapter
Power
Reset
Internet
1
2
3
4
Router
AC/DC
Adapter
AC Input
12 VDC
Power
AC Pwr
Power
Figure 31:  Power Wiring
Figure 32:  Power Strip for Control Unit and Modem
Do not cut off the ground pin from the control 
unit and modem power cable plugs, and do 
not use a 3-prong to 2-prong adapter.
IMPORTANT!
Double-check all of your wiring before 
continuing. If wiring is incomplete or 
incorrect, electronics may become damaged 
when you apply power.
IMPORTANT!
Connect Power