Insignia NS-R5101 用户手册

下载
页码 108
4
Insignia NS-R5101 5.1 Surround Sound A/V Receiver
www.insignia-products.com
Important safety instructions
All of these safety and operating instructions 
should be read before your receiver is 
operated.
The safety, operation, and use instructions 
should be retained for future reference.
All warnings on your receiver and in the 
operating instructions should be adhered to.
All operation and use instructions should be 
followed.
Do not use this receiver near water. For 
example, do not use this receiver near a bath 
tub, wash bowl, kitchen sink, laundry tub, in a 
wet basement, near a swimming pool, and 
other areas located near water.
Clean only with dry cloth. Unplug this 
receiver from the wall outlet before cleaning. 
Do not use liquid cleaners.
Do not block any ventilation openings. Install 
in accordance with these instructions. Slots 
and openings in the cabinet are provided for 
ventilation, to ensure reliable operation of 
your receiver, and to protect it from 
over-heating. The openings should never be 
blocked by placing your receiver on a bed, 
sofa, rug, or other similar surface. This 
receiver should not be placed in a built-in 
installation such as a bookcase or rack 
unless correct ventilation is provided or these 
instructions have been adhered to.
Do not install near any heat sources such as 
radiators, heat registers, stoves, or other 
electronic devices (including amplifiers) that 
produce heat.
Do not defeat the safety purpose of the 
polarized or grounding-type plug. A polarized 
plug has two blades with one wider than the 
other. A grounding type plug has two blades 
and a third grounding prong. The wide blade 
or the third prong are provided for your safety. 
If the provided plug does not fit into your 
outlet, consult an electrician for replacement 
of the obsolete outlet.
Protect the power cord from being walked on 
or pinched, particularly at plugs, receptacles, 
and the point where they exit from your 
receiver.
Use only attachments or accessories 
specified by Insignia.
Use only with a cart, 
stand, tripod, bracket, or 
table specified by 
Insignia, or sold with this 
receiver. When a cart is 
used, use caution when 
moving the cart/receiver 
combination to avoid 
injury from tip-over.
If an outside antenna or cable system is 
connected to your receiver, make sure that 
the antenna or cable system is grounded to 
provide some protection against voltage 
surges and built-up static charges. Article 
810 of the National Electrical Code, 
ANSI/NFPA 70, provides information with 
regard to proper grounding of the mast and 
supporting structure, grounding of the lead-in 
wire to an antenna discharge unit, size of 
grounding conductors, location of 
antenna-discharge unit, connection to 
grounding electrodes, and requirements for 
the grounding electrode.
Use No. 10 AWG (5.3 mm
2
) copper, 
No. 8 AWG (8.4 mm
2
) aluminum, 
No. 17 AWG (1.0 mm
2
) copper-clad steel 
or bronze wire, or larger, as a ground wire.
Secure the antenna lead-in and ground 
wires to the house with stand-off 
insulators spaced from 4-6 feet 
(1.22-1.83 meter) apart.
Mount the antenna discharge unit as 
close as possible to where the lead-in 
enters the house.
Use a jumper wire not smaller than 
No. 6 AWG (13.3 mm
2
) copper, or the 
equivalent, when a separate 
antenna-grounding electrode is used. See 
ANSI/NFPA70.
Unplug this receiver during lightning storms 
or when unused for long periods of time.
Caution
Read and observe all warnings and instructions in this manual 
and those marked on your receiver. Retain this manual for 
future reference.
This receiver has been designed and manufactured to ensure 
personal safety. Improper use can result in electric shock or 
fire hazard. The safeguards incorporated in this receiver will 
protect you if you observe the following procedures for 
installation, use, and servicing. This receiver does not contain 
any parts that can be repaired by you.
Do not remove the cabinet cover or you may be exposed to 
dangerous voltage. Refer servicing to qualified service 
personnel only.
Reference Grounding component
1
Electric service equipment
2
Power service grounding electrode 
system (NEC Art 250, Part H)
3
Ground clamp
4
Grounding conductors (NEC 
Section 810-21)
5
Antenna discharge unit (NEC 
Section 810-20)
6
Ground clamp
7
Antenna lead-in wire
6
7
5
2
1
3
4