1.2  General Specification Summary 
PARAMETER 
VALUE 
Power Input 
 
 
Voltage Range 
80-160 VDC;  120 VDC nominal 
 
Maximum Current
 
20 A 
 
Typical Transient Current
 
+20A < 60ms;  +10A < 120ms;  -5A < 100ms 
 
Typical Continuous Current
 
< 1A 
 
 
Inputs and Outputs 
 
 
Discrete Inputs
 
 
 
 
RUN and RESET commands
 
 
 
ON Voltage:
  
12 – 32 VDC,  
 
 
+24 VDC nominal @ 6.5 mA 
OFF Voltage:
  
1.0 VDC, maximum 
 
Discrete Outputs
 
 
 
 
FAULT &  OVERTEMP alarms 
 
OFF Voltage:
    
32 VDC maximum @ 150 µA typical 
Effective ON Resistance
  
1.1 kΏ, nominal 
@ ≥ 1.5 VDC:
 
 
 
Analog Input
 
 
 
DEMAND command signal 
Current: 4 to 20 mA; 25 mA Maximum 
Voltage: 5 VDC Maximum 
Internal Impedance:  200 Ώ 
 
Analog Outputs
 
 
 
POSITION & MTR
 
CURRENT feedback 
Current: 4 to 20 mA  
External Load Resistance:  300 Ώ, Maximum 
 
Maximum Common Mode Voltage 
±200 VDC User I/O to 120 VDC Return (less serial interface) 
 
 
Performance 
All performance values are based on use with HFG2.0 in default configuration. 
Any changes to HFG2.0 firmware settings to change stroke profile will alter 
performance values. 
 
Maximum Operating Pressure 
500 psig 
 
Proof Pressure 
2000 psig 
 
Minimum Controllable Flow (Natural Gas) 
15 pph (configuration dependent) 
 
Maximum Controllable Flow 
30,000 pph (configuration dependent) 
 
Step Response (10% to 90%) 
100 ms 
 
Flow Accuracy 
± 5% of flow point, typical 
 
Mean Time Before Unscheduled Removal
 
30,000 Hours 
 
Life Cycles 
32,000 Minimum 
 
 
Environmental 
 
 
Temperature, Operating Ambient: 
-40
° C (-40° F) to +93° C (+200° F) 
 
Temperature, Operating Fuel: 
-40
° C (-40° F) to +125° C (+257° F) 
 
Temperature, Storage 
-40
° C (-40° F) to +125° C (+257° F) 
 
Environmental Rating 
Rated to CSA Type 3 and European IP65 
Sealed against dust, protected against water 
 
EMC 
Meets EN 50081-2 and EN50082-2 for DC powered industrial equipment 
 
Vibration 
Meets Mil-Std-810E, Category 4 (5 – 2000 Hz) 
 
INSTALLING THE HFG2.0 
3