Cisco Systems WS-X6608-T1 用户手册

下载
页码 128
B-46
Ci sco Catalyst  4900M Swit ch I nst allati on Guide
78-18350-02
Appendi x B      Compliance Inf ormat ion and Translat ed Safet y Warnings
  GR-1089-CORE Issue 3 Documentat ion Statements
Statement 294—Class A Warning for Korea
GR-1089-CORE Issue 3 Documentation Statements
Statement 7016—GR-1089-Core Intrabuilding Lightning—Immunity 
Requirements
Caution
To co mply with GR-1089 -Core intrabuild ing lightning -immunity  req uirements, yo u must use shielded 
(screen ed) cable th at is gro unded at both  ends.
GR-1089-CORE Issue 4 Documentation Statements
Statement 7001—ESD Mitigation
This equ ipmen t may be ESD sens itive. Always use an ESD ankle or wrist strap b efore handling 
equip ment. Connect the equ ipmen t end of th e ESD strap  to  an unfin ished s urface of the equipment 
chassis or to the ESD jack on the equ ipmen t if p rovid ed.
Statement 7005—Intra-building Lightning Surge and AC Power Fault
Warning
The intra-buil ding port( s) of  the equipment or subassembly is suitable for connection to intra-bui lding 
or unexposed wiring or cabling only. The intra-building port(s) of the equipment or subassembly 
MUST NOT metallical ly connect to interfaces t hat connect to the OSP or its wiring. These interfaces 
are designed for use as i ntra-building interfaces only (Type 2 or Type 4 ports as descri bed in 
GR-1089-CORE, Issue 4) and require i solation from the exposed OSP cabling. The addi tion of Primary 
Protectors is not sufficient protection in order to connect these interfaces metallically to OSP wiring.
Warning
This is a Class A Device and is registered for EMC requirements for industrial use. The seller or 
buyer should be aware of this. If this type was sold or purchased by mistake, it should be replaced 
with a residenti al-use type.