Cisco Systems WS-X6608-T1 用户手册
1-3
Cisco Cat alyst 4900M Sw itch Instal lation Guid e
78-18350-02
Chapter 1 Product Overview
Catalyst 4900M Swi tch Chassis
Note
A console cable is not provided as part of the accessory kit. It is available as an op tio n.
Catalyst 4900M Switch Chassis Physical and Environmental Specifications
lists the Cataly st 4 900M switch chas sis environmental and physical sp ecificatio ns.
Reset switch
Th e Reset button is used to restart the switch. Use a p ap er clip o r oth er small,
po inted ob ject to p ress the Reset button .
po inted ob ject to p ress the Reset button .
Fan tray
Variable-speed. Field replaceable.
Power sup plies
10 00 W AC-in put and 1 000 W DC-inpu t power supplies are su pported.
Table 1-1
Catalyst 4900M Switch Features (continued)
Feature
Description
Table 1-2
Catalyst 4900M Switch Specifications
Item
Specification
Environmental
Temp eratu re, op erating
Certified for operation: 32 ° to 1 04°F (0 ° to 40° C)
Design ed and tested for operation : 3 2° to 131°F (0° to 55°C)
Note
The Catalyst 4900M s witch is equ ipped with internal air temperature
sens ors that are triggered at 49 °C (120.2°F) generating a minor alarm
and at 64°C (147.2°F) generating a major alarm. The system will shut
down at 67°C (152.6°F).
sens ors that are triggered at 49 °C (120.2°F) generating a minor alarm
and at 64°C (147.2°F) generating a major alarm. The system will shut
down at 67°C (152.6°F).
Temp eratu re, no noperating
and storag e
and storag e
–40 ° to 167°F (–40° to 75°C)
Humidity (RH), ambient
(noncondensin g) operating
(noncondensin g) operating
10 % to 90%
Altitu de, operating
Certified for operation: –1 97 to 6562 ft (–60 to 2000 m)
Heat Dissipation
13 64 BTU/ho ur (worst case)
Physical Characteristics
Dimensio ns (H x W x D)
•
3.5 x 17.2 x 17.9 in. (8.9 x 4 3.7 x 4 5.5 cm).
•
Chassis requires 2 RU
1
.
.
•
Th e Catalyst 490 0M switch chassis is designed to in stall in standard
19 -inch eq uipment racks that meet ANSI/EIA 310-D, IEC 602 97, and
ETS 30 0-1 19 stan dards.
19 -inch eq uipment racks that meet ANSI/EIA 310-D, IEC 602 97, and
ETS 30 0-1 19 stan dards.
1.
RU = rack un its
Weight
34 .0 lb (15.4 kg) (max)
Airflow
151.7 CFM (max)