Cisco Systems WS-X6608-T1 用户手册

下载
页码 128
1-7
Cisco Cat alyst 4900M Sw itch Instal lation Guid e
78-18350-02
Chapter 1      Product Overview
  Catalyst 4900M Swi tch Chassis
Figure  1-4
Catalyst 4900M Chassis Airflow
There are five fans in the fan tray. If an in dividual fan fails , the o ther fans co ntinue to  run. Senso rs 
monitor the  internal air  temperatures. The  number of fan s in  operation  and  their sp eed  varies  according 
to the intern al temperature for the quietest o peration possible. If the air temperature exceeds a desired 
thresho ld, the environmental mon itor disp lays warning mes sages. 
Note
Ind iv idual fan s in  the fan tray canno t be replaced; the entire fan tray must be replaced.
Power Supplies
Note
Fo r co mplete power specification s for th e Catalyst 490 0M s witch,  see Appendix  A, “
.”
The Catalyst 4900M  switch  has  two  redu ndant in ternal 1 000 W AC-input or 10 00 W DC-input power 
supplies. 
The internal p ower supp lies have individu al power cords an d status LEDs (PS1 an d PS2 on the front 
panel). Th ere are also LEDs o n the power supp lies that show status for th e input (Inpu t OK) and o utput 
(Output OK) cu rren ts. A power cord is used to con nect the power su pplies to the site AC so urce. There 
is a power switch  on  th e AC-inp ut power supp lies; AC power is present when a power cord is plugged 
into a power supply and the switch  is set to  th e On  po sition. DC-inp ut p ower supp lies attach to source 
DC using customer-supplied cables.
The switch  starts  with  only  one p ower  supply  plug ged  in, bu t redu ndant failover and  load  sharin g is  not 
availab le in this co nfiguration. Cisco recommen ds that you  always co nnect both  power supplies to 
sep arate AC o r DC circuits for o ptimal power reliability.
232124