CL4490 User’s Manual
 
5.  Troubleshooting 
Solution 
Problem 
CL4490 
CN4490 
Read Radio 
displays error 
message: 
“Radio not 
responding.” 
1.  Make sure the PC Settings are right. See Section 
4.2.3 PC Settings. 
2.  Make sure the CL4490 unit uses the right serial 
cable.  Refer to Section 2.1 RS-232
3.  If any other program that is using the same COM 
port as CL4490 is open, close that program and 
try to read the radio again. 
4.  Reset the radio by cycling power after each 
unsuccessful Read.  
1.  Make sure the PC Settings are right. See 
Section 7.2.3 PC Settings. 
2.  Make sure the
 
CN4490
 
unit uses the right 
Ethernet cable.  Refer to Section 2.2 LAN Port
3.  If any other program that is using the same 
LAN port as CN4490 is open, close that 
program and try to read the radio again. 
4.  Reset the radio by cycling power after each 
unsuccessful Read.  
Write Radio 
displays error 
message: 
“Radio not 
responding.” 
1. 
Cycle power to the radio. 
2. 
Read the radio and make desired changes and 
then Write the radio. 
 
1. Cycle power to the radio. 
2. Read the radio and make desired changes 
and then Write the radio. 
 
Garbled Data 
received. 
1.  Check Data Encryption Standard settings.  
1.   Check Data Encryption Standard    settings. 
Client’s Link 
LED does not 
come on. 
1.  Make sure the unit is connected to power. 
2.  Cycle power to the radio. 
 
1.    Make sure Server CN4490 unit is                 
powered up. 
2.    Cycle power to the radio. 
Link LED is 
on, but data 
does not get 
transmitted or 
received. 
1.  Make sure the CL4490 unit(s) is connected to the 
correct COM Port. 
2.  Check the COM port settings for correct Baud 
RateParity and either Hardware or No Flow 
Control
.  Units can have transmission errors 
with Flow Control set to Xon/Xoff
3. Try 
increasing 
the 
Maximum Transmit 
Attempts (for Clients) and/or Broadcast 
Attempts
 (for Servers) values in small 
increments until communication is established. 
4. Connect 
Null Modem adapter between the 
Client and its host device. 
5.  Check the Destination Address setting. 
 1.    Make sure the CN4490 unit(s) IP   Address 
is right. 
2.    Try increasing the Maximum Transmit 
Attempts
 (for Clients) and/or Broadcast 
Attempts
 (for Servers) values in small 
increments until communication is established. 
3.    Check the Destination Address setting. 
If these troubleshooting tips do not resolve the problem, please call our toll free number at    (800) 
492-2320, extension 228.  Technical support hours are Monday through Friday, 8:00 am to 5:00 
pm Central Standard Time. 