Adder Technology ADDERLINK X2 用户手册

下载
页码 31
6



 


REMOTE module switches
REMOTE module switches (continued)
REMOTE Switch 1
OFF: Normal operation.
ON: (Before power is applied) Places the REMOTE module into flash upgrade 
mode so that the internal software can be changed. Please see the ‘Flash 
upgrade’ section in the ‘Special configuration’ chapter.
REMOTE Switches 2 and 3
Switches 2 and 3 determine which two keyboard keys (when pressed in unison) 
are to be designated as ‘hotkeys’. Hotkeys signal to the REMOTE module that 
the next key to be pressed is a special configuration command for the module 
and is not to be passed to the computer system.
2 OFF
3 OFF  
Hotkeys = CTRL and SHIFT
2 OFF
3 ON  
Hotkeys = ALT and SHIFT
2 ON
3 OFF  
Hotkeys = CTRL and ALT
2 ON
3 ON  
Hotkeys disabled
REMOTE Switch 4
This switch is reserved for future use. 
Note: When shipped, all switches are set in the OFF positions and this will 
produce normal operation.
Determines configuration
of hotkeys in conjunction
with switch 3
Reserved for 
future use
OFF: Normal operation
ON: Flash upgrade
Determines configuration 
of hotkeys in conjunction 
with switch 2
1
ON
2
3
4
1
ON
4
2 3
ON