electrIcal data
General
Check the water heater model and rating plate information against 
the  characteristics  of  the  branch  circuit  electrical  supply.  Do  not 
connect the heater to an improper source of electricity. 
Voltage  applied  to  the  water  heater  should  not  vary  more  than 
+5% to -10% of the model and rating plate marking for satisfactory 
operation.
Do NOT energize the branch circuit for any reason before the water 
heater tank is filled with water.
The installation must conform to these instructions and the local code 
authority having jurisdiction. Grounding and electrical wiring connected 
to  the  water  heater  must  also  conform  to  the  National  Electrical 
Code, NFPA 70. This publication is available from The National Fire 
Protection Association, 1 Batterymarch Park, Quincy, MA 02269.
Branch cIrcuIt
The branch circuit wire size should be established through reference 
to  the  NEC  (National  Electrical  Code)  or  other  locally  approved 
sources in conjunction with the water heater amperage rating.. Wire 
rated at 75°C should be used. Voltage drop should not exceed 3% 
at the water heater.
control cIrcuIts
The  water  heater  may  be  equipped  with  an  electronic  control 
system.  The  typical  system  includes  an  electronic  controller,  an 
immersion temperature probe auto reset high limit, electric valve 
activator  and  integral  circulator  pump.  Refer  to  control  circuit 
diagram  provided  with  the  HWG  for  wiring  details.  The  actuator 
is powered by a small 120V/24V transformer. The control circuit 
operates  on  120V.  Please  see  attached  wiring  diagrams  for 
appropriate wiring and connections.
therMal expansIon
As  water  is  heated,  it  expands  (thermal  expansion).  In  a  closed 
system  the  volume  of  water  will  grow  when  it  is  heated. As  the 
volume of water grows there will be a corresponding increase in 
water pressure due to thermal expansion. Thermal expansion can 
cause premature tank failure (leakage). This type of failure is not 
covered  under  the  limited  warranty. Thermal  expansion  can  also 
cause  intermittent  temperature-pressure  relief  valve  operation: 
water discharged from the valve due to excessive pressure build 
up. This condition is not covered under the limited warranty. The 
temperature-pressure relief valve is not intended for the constant 
relief of thermal expansion.
A properly sized thermal expansion tank should be installed on all 
closed systems to control the harmful effects of thermal expansion. 
Contact a local plumbing service agency to have a thermal expansion 
tank installed.
steaM supply (steaM unIts only)
This water heater is designed to use saturated steam.  Superheated 
steam, even small amounts, will cause some or all of the following:
•  Excessive fouling of the heat exchanger
•  Excessive batch heating times
•  Reduced recovery rate
•  Reduced steam flow
If  superheated  steam  exists  in  the  system,  a  device,  such  as  a  de-
superheater, must be installed in the steam line supplying this water heater.
checkInG for tIGhtness
Threaded and bolted connection can vibrate loose during transit. Prior to 
insulating any of the water heater trim piping or the heat exchanger flange, 
insure that all the piping connections and the flange gasket are tight by filling 
the system with water and operating it at the desired system pressure.