Safety - 16
PR95 Operator’s Manual
Emergency Procedures
CMW
If an Electric Line is Damaged
If you suspect an electric line has been damaged and you are in pit, DO NOT MOVE. Remain in pit and 
take the following actions. The order and degree of action will depend upon the situation.
Warn people nearby that an electric strike has occurred. Instruct them to leave the area and contact 
utility.
Contact utility company to shut off power.
Do not leave pit until given permission by utility company.
If you suspect an electric line has been damaged and you are out of pit, DO NOT TOUCH ANYTHING IN 
PIT. Take the following actions. The order and degree of action will depend upon the situation.
LEAVE AREA. The ground surface may be electrified, so take small steps with feet close together to 
reduce the hazard of being shocked from one foot to the other. For more information, contact your 
Ditch Witch dealer.
Contact utility company to shut off power.
Do not return to jobsite or allow anyone into area until given permission by utility company.
If you suspect an electric line has been damaged and you are on other piece of equipment, DO NOT 
MOVE. Remain on truck or trailer and take the following actions. The order and degree of action will 
depend on the situation.
Warn people nearby that an electric strike has occurred. Instruct them to leave the area and contact 
utility.
Contact utility company to shut off power.
Do not return to area or allow anyone into area until given permission by utility company.
If you suspect an electric line has been damaged and you are off other piece of equipment, DO NOT 
TOUCH EQUIPMENT. Take the following actions. The order and degree of action will depend on the 
situation.
LEAVE AREA.
Contact utility company to shut off power.
Do not return to area or allow anyone into area until given permission by utility company.