Incoming Retried Messages 
This value is number of successful 
receptions that indicated that they 
retried by the sending application. If 
displayed in yellow, this value is more 
than 1.5% of the Successful Incoming 
Messages. 
Total Outgoing Messages 
This value is total number of outgoing 
messages sent on this port. 
Outgoing Retried Messages 
This value is number of outgoing 
messages that were retried because the 
receiving application did not 
acknowledge them. If displayed in 
yellow, this value is more than 1.5% of 
the Total Outgoing Messages. 
Receiver Buffer Max 
This value is maximum number of bytes 
received on this serial port, but not 
yet processed by the system. If 
displayed in yellow, more than 50% of 
the queue was in use. 
Transmit Buffer Max 
This value is maximum number of bytes 
processed by the system, but not yet 
transmitted on this serial port. If 
displayed in yellow, more than 50% of 
the queue was in use. 
Buffer Overflow 
This is the number of times a byte was 
lost by the software for a serial port 
because the input buffer overflowed. 
Bytes were placed into the input buffer 
faster than the system could process 
them. 
Hardware Overrun 
This is the number of times a byte was 
lost by the hardware for a serial port 
because it was not fast enough to 
process the byte into the input buffer. 
Total Remote Access Connections 
This value is the total number of times 
a remote access connection was 
successful. 
Total Wrong Access Code Attempts 
This value is the number of times a 
remote access connection was attempted 
and rejected because a valid remote 
access code was not received. 
Last Remote Access Time 
This is the time and date of the last 
successful remote access attempt. 
Successful Pager Messages 
This value is the number of successful 
pager messages sent. 
Failed Pager Attempts 
This value is the number of times a 
pager message dial-out was 
unsuccessful. 
Reset Status 
Pressing this button resets all values 
shown in this screen. 
Refresh Data 
Pressing this button refreshes all 
values shown in this screen. The values 
are not automatically updated when the 
screen is left open. 
3.3.16 
System Status Screen 
This screen shows the status of 
internal system queues and 
communications on the serial ports 
assigned to transponders. 
Figure 511: System Status Screen 
 
Maximum Retry Messages 
This value is maximum number of 
unacknowledged messages in queue to be 
sent to all transponders in the system. 
If displayed in yellow, more than 50% 
of the queue was in use at this value. 
Maximum Alarm Messages 
This value is the maximum number of 
alarms that the system processed at it 
busiest time. If displayed in yellow, 
more than 50% of the maximum was in 
use. 
Maximum Trouble Messages 
This value is the maximum number of 
troubles in the queue yet to be 
displayed. If displayed in yellow, more 