Bosch Appliances Home Security System ICP-CC404 用户手册

下载
页码 98
ICP-CC404 | Installation Guide | 3.0  
Codepad Indicators 
 
 
16 Bosch 
Security 
Systems, 
Inc. | 12/08 | F01U089401-02
 
3.0   Codepad Indicators 
3.1 
ICP-CP508W Eight Zone LED 
Codepad 
Figure 1: 
ICP-CP508W Eight Zone LED 
Codepad 
 
 
The codepad is the communications interface 
between you and the alarm system. The codepad 
allows you to issue commands and offers visual and 
audible indications to guide you through general 
operation. 
The codepad incorporates a number of indicators: 
eight zone indicators show the condition of each zone 
and four other indicators show general status. These 
indicators are described in Table 8 through Table 13 
on page 17.  
Zone Indicators 
 
Table 8: 
Zone Indicators 
 
Indicator Definition 
On 
The zone is unsealed 
Off 
The zone is sealed 
Flashing fast 
(0.25 sec on/0.25 sec off) 
The zone is in alarm 
Flashing slow 
(1 sec on/1 sec off) 
The zone is manually 
isolated 
 
STAY Indicator 
The STAY indicator lights when the system is armed 
in STAY Mode 1 or STAY Mode 2. The STAY 
indicator flashes with the AWAY indicator when you 
are in Installer’s Programming Mode or you are using 
a Master Code function. 
For more information, refer to: 
•  Section 4.3 on page 19 to arm the system in STAY 
Mode 1.  
•  Section 14.3.4 on page 57 to set zones to 
automatically isolate in STAY Mode 1.  
•  Section 4.5 on page 20 to arm the system in STAY 
Mode 2.   
•  Section 6.1.4 on page 30 to use the Installer Code 
to set zones to automatically isolate in STAY 
Mode 2. 
•  Section 6.2.5 on page 35 to use the Master Code 
to set zones to automatically isolate in STAY 
Mode 2. 
 
Table 9: 
STAY Indicator 
 
Indicator Definition 
On 
The system is armed in STAY Mode 1 or 
STAY Mode 2 
Off 
The system is not armed in STAY Mode 1 or 
STAY Mode 2 
Flashing 
Zone Isolating Mode or setting STAY Mode 2 
zones 
 
AWAY Indicator 
The AWAY indicator lights when the system is 
armed in AWAY Mode. The AWAY indicator flashes 
with the STAY indicator when you are in Installer’s 
Programming Mode or you are using a Master Code 
function. 
Refer to Section 4.1 Arming the System in AWAY Mode 
on page 18 for more information. 
 
Table 10: 
AWAY Indicator 
 
Indicator Definition 
On 
The system is armed in AWAY Mode 
Off 
The system is not armed in AWAY Mode 
 
MAINS Indicator 
The MAINS indicator shows whether the system’s 
AC MAINS supply is normal or failed.  
When programming in Installer’s Programming 
Mode or using a Master Code function, the MAINS 
indicator lights to indicate a location value from 10 
to 15. The MAINS indicator represents the 10 digit, 
which is added to the value of the lit zone indicator 
(for example, if the value programmed in a location 
is 12, the MAINS and Zone 2 indicators light). 
 
Table 11: 
MAINS Indicator 
 
Indicator Definition 
On 
The AC MAINS power is normal 
Flashing 
The AC MAINS supply failed 
 
FAULT Indicator 
The FAULT indicator lights when the system detects 
a system fault. Refer to Section 4.12 Fault Analysis Mode 
on page 22 for more information on system faults. 
Each time a new system fault is detected (the FAULT 
indicator flashes), the codepad beeps once per 
minute. 
Press [AWAY] to stop the beeping and to 
acknowledge the fault.