ICP-CC404 | Installation Guide | 4.0  
System Operations 
 
 
22 Bosch 
Security 
Systems, 
Inc. | 12/08 | F01U089401-02
 
2.  Enter the number of the zone to isolate and press 
[STAY].   
The indicator for the zone flashes. 
24-Hour zones are automatically isolated as soon 
as you press [STAY]. All other Burglary Zones 
are automatically isolated only after the system is 
armed. 
3.  Repeat Step 2 for each zone you want to isolate. 
 
 
As each zone is selected to isolate, the 
corresponding zone indicator flashes. If 
you make a mistake, enter the incorrect 
zone number and press [STAY]. This 
zone is no longer selected to isolate and 
the zone indicator turns off. 
 
4.  Press [AWAY].   
Two beeps sound and the system returns to the 
disarmed state. 
The indicators for the selected zones continue to 
flash until the next time the system is disarmed. 
Example 
To manually isolate zones 1, 3, and 4, press: 
[STAY][STAY][1][STAY][3][STAY][4][STAY] 
[AWAY] 
4.11.2  Code to Isolate 
The code to isolate method permits only those User 
Code holders with a priority level that includes Code 
to Isolate. The standard isolating method is disabled 
for any User Code with this priority level. 
1.  Press [STAY]. 
2.  Enter your code and press [STAY].   
Three beeps sound and the STAY indicator 
flashes. 
If you attempt to enter Isolating Mode with a 
User Code that is not set for Code to Isolate, the 
system ignores the attempt. 
3.  Enter the number of the zone to isolate and press 
[STAY].   
The indicator for the zone flashes. 
24-Hour zones are automatically isolated as soon 
you press [STAY]. All other burglary zones are 
automatically isolated only after the system is 
armed. 
4.  Repeat Step 3 for each zone to isolate. 
 
 
As each zone is selected to isolate, the 
corresponding zone indicator flashes. If 
you make a mistake, enter the incorrect 
zone number and press [STAY]. This 
zone is no longer selected to isolate and 
the zone indicator turns off. 
 
5.  Press [AWAY].   
Two beeps sound and the system returns to the 
disarmed state. 
The indicators for the selected zones continue to 
flash until the next time the system is disarmed. 
Example 
To manually isolate zones 1, 3, and 4, press: 
[STAY][User Code][STAY][1][STAY][3][STAY][4] 
[STAY][AWAY] 
4.12 Fault 
Analysis 
Mode 
Whenever a system fault occurs, the FAULT or 
MAINS indicator flashes and the codepad beeps once 
per minute. 
If the MAINS indicator flashes, the AC MAINS 
supply is disconnected from the control panel. Refer 
to AC MAINS Failure on page 24. 
To enter Fault Analysis Mode to determine a system 
fault other than the AC MAINS supply: 
1.  Press and hold [5] until two beeps sound. 
The FAULT indicator remains lit and the STAY 
and AWAY indicators flash. 
The lit zone indicators indicate the type of fault 
that occurred. Refer to Table 14
2.  To exit from the Fault Analysis Mode, press 
[AWAY]. 
The STAY and AWAY indicators turn off and 
the FAULT indicator remains lit. 
 
Table 14: 
Fault Indicators 
 
Indicator Fault 
Description 
Low battery 
2 Date 
and 
time 
Sensor watch 
4 Horn 
speaker 
disconnected 
Telephone line fault 
6 EEPROM 
fail 
AUX Power Supply fail 
8 Communications 
failure 
 
4.13 Fault 
Descriptions 
1 – Low Battery 
A low battery fault occurs when the battery supply 
voltage falls below 11.2 VDC or when a Dynamic 
Battery Test detects a low capacity battery. This fault 
clears after a successful Dynamic Battery Test. The 
system performs a Dynamic Battery Test every 4 
hours after power is connected to the control panel 
and every time the system is armed.   
When reporting to the base station receiver, the 
control panel sends a Battery Test Failure Report 
(Contact ID Event Code 309) to indicate the low 
battery fault.