Location 332 (Section 15.5 Zone Status Reporting Options 
on page 61) is ignored when programming the Alarm 
Restore code and is global for all zones. A zone 
Restore Report is sent only to the receiving party to 
which the zone is allocated (for example, Receiver 1 
or Receiver 2). 
15.5  Zone Status Reporting Options 
Use 
Location 332 to select whether Zone Status 
Reports are sent to Receiver 1 (the default), 
Receiver 2, or both, Receiver 2 only when Receiver 1 
fails, or there is no reporting at all. Table 46 lists the 
reporting options. 
 
Table 46: 
Zone Status Reporting Options 
 
Option Description 
No report required 
1 Receiver 
Receiver 2 
Receiver 1 and Receiver 2 
Receiver 2 only when Receiver 1 fails 
 
15.6 Open/Close 
Reports 
Program the Open Report value in 
Location 333 (the 
default value is 
11) and the Close Report value in 
Location 334 (default 12). 
An Opening Report (Contact ID Event Code 401) is 
sent to the base station receiver when the system is 
disarmed from AWAY Mode. A Closing Report 
(Contact ID Event Code 401) is sent at the end of 
Exit Time when the system is armed in AWAY 
Mode.   
If an expanded format is selected, this code is used as 
the Expansion Code and the user number that armed 
or disarmed the system follows in the same 
transmission. 
To enable Open and Close Reports in STAY Mode, 
select Option 2 in Location 178 (refer to Section 12.2 
Dialer Options 2
 on page 50). To enable Open and 
Close Reports only after a previous alarm, select 
Option 1 in Location 178. 
 
 
If Open and Close Reports are not 
required, program Locations 333 and 
334 as 0. 
 
15.7 Open/Close 
Reporting 
Options 
Use 
Location 335 to select whether Zone Status 
Reports are sent to Receiver 1 (the default), 
Receiver 2, or both, Receiver 2 only when Receiver 1 
fails, or there is no reporting at all. Table 47 lists the 
reporting options. 
 
Table 47: 
Open/Close Reporting Options 
 
Option Description 
No Open/Close Reports required 
1 Receiver 
Receiver 2 
Receiver 1 and Receiver 2 
Receiver 2 only when Receiver 1 fails 
 
15.8  Codepad Duress Report 
Program the Codepad Duress Report value in 
Location 336. 
The default value is 
6. 
A Duress Report (Contact ID Event Code 121) is sent 
to the base station receiver when a user adds 9 to the 
end of any valid User Code used to disarm the 
system. This alarm is always silent. A Duress Alarm 
can be activated during Exit Time (in other words, if 
the system is armed and then disarmed with a 9 at the 
end of the User Code before Exit Time expires, a 
Duress Report is sent). Adding 9 to the end of a User 
Code when arming the system does not cause a 
Duress Alarm.  
If you want a 3 to activate a Codepad Duress Alarm 
instead of 9, select Option 2 in Location 430 (refer to 
Section 18.7 Consumer Options 3 on page 75). 
 
Restore Reports are not sent for this 
event.  
If Duress Reports are not required, 
program Location 336 as 0. 
 
15.9  Codepad Panic Report 
Program the Codepad Panic Report value in 
Location 337 (tens digit) and Location 338 (units 
digit). 
The default values are 
7 (tens) and 15 (units). 
A Panic Alarm Report (Contact ID Event Code 120) 
is sent to the base station receiver when a user presses 
either [1] and [3] or [STAY] and [AWAY] at the same 
time. A Panic Alarm is audible, but you can program 
the alarm as silent by selecting Option 1 in Location 
425 (refer to Section 18.2 System Options 2 on page 73). 
 
Restore Reports are not sent for this 
event.  
If Panic Reports are not required, 
program Locations 337 and 338 as 0. 
 
15.10  Codepad Fire Report 
Program the Codepad Fire Report value in 
Location 
339 (tens digit) and Location 340 (units digit). 
The default values are 
7 (tens) and 14 (units).